Launched in 2004, dmesgd aims to provide a user-submitted repository of searchable *BSD dmesgs. The dmesg(8) command displays the system message buffer's content, and during boot a copy is saved to /var/run/dmesg.boot. This buffer contains the operating system release, name and version, a list of devices identified, plus a whole host of other useful information. We hope others find this resource useful and further contribute to its growth. Contact us at [ admin at lists dot nycbug dot org ]. Note that this site is not a substitute for sending the dmesg directly to the respective project.
Date: 2022-12-15 03:12:17
From: JE3KMZ
Description: FreeBSD/amd64 on Dell Inc. PowerEdge T110 II
Copyright (c) 1992-2021 The FreeBSD Project. Copyright (c) 1979, 1980, 1983, 1986, 1988, 1989, 1991, 1992, 1993, 1994 The Regents of the University of California. All rights reserved. FreeBSD is a registered trademark of The FreeBSD Foundation. FreeBSD 13.1-RELEASE-p3 GENERIC amd64 FreeBSD clang version 13.0.0 ([_EMAIL_XXXXX]:llvm/llvm-project.git llvmorg-13.0.0-0-gd7b669b3a303) VT(vga): resolution 640x480 CPU microcode: updated from 0x29 to 0x2f CPU: Intel(R) Pentium(R) CPU G645 @ 2.90GHz (2893.55-MHz K8-class CPU) Origin="GenuineIntel" Id=0x206a7 Family=0x6 Model=0x2a Stepping=7 Features=0xbfebfbff<FPU,VME,DE,PSE,TSC,MSR,PAE,MCE,CX8,APIC,SEP,MTRR,PGE,MCA,CMOV,PAT,PSE36,CLFLUSH,DTS,ACPI,MMX,FXSR,SSE,SSE2,SS,HTT,TM,PBE> Features2=0xd9ae3bf<SSE3,PCLMULQDQ,DTES64,MON,DS_CPL,VMX,EST,TM2,SSSE3,CX16,xTPR,PDCM,PCID,SSE4.1,SSE4.2,POPCNT,TSCDLT,XSAVE,OSXSAVE> AMD Features=0x28100800<SYSCALL,NX,RDTSCP,LM> AMD Features2=0x1<LAHF> Structured Extended Features3=0x9c000400<MD_CLEAR,IBPB,STIBP,L1DFL,SSBD> XSAVE Features=0x1<XSAVEOPT> VT-x: (disabled in BIOS) PAT,HLT,MTF,PAUSE,EPT,UG,VPID TSC: P-state invariant, performance statistics real memory = 4294967296 (4096 MB) avail memory = 4033253376 (3846 MB) Event timer "LAPIC" quality 600 ACPI APIC Table: <DELL PE_SC3 > FreeBSD/SMP: Multiprocessor System Detected: 2 CPUs FreeBSD/SMP: 1 package(s) x 2 core(s) random: unblocking device. ioapic0 <Version 2.0> irqs 0-23 Launching APs: 1 random: entropy device external interface kbd1 at kbdmux0 WARNING: Device "spkr" is Giant locked and may be deleted before FreeBSD 14.0. vtvga0: <VT VGA driver> smbios0: <System Management BIOS> at iomem 0xfe120-0xfe13e smbios0: Version: 2.7, BCD Revision: 2.7 aesni0: No AES or SHA support. acpi0: <DELL PE_SC3> acpi0: Power Button (fixed) cpu0: <ACPI CPU> on acpi0 hpet0: <High Precision Event Timer> iomem 0xfed00000-0xfed003ff on acpi0 Timecounter "HPET" frequency 14318180 Hz quality 950 Event timer "HPET" frequency 14318180 Hz quality 550 Event timer "HPET1" frequency 14318180 Hz quality 440 Event timer "HPET2" frequency 14318180 Hz quality 440 Event timer "HPET3" frequency 14318180 Hz quality 440 Event timer "HPET4" frequency 14318180 Hz quality 440 Event timer "HPET5" frequency 14318180 Hz quality 440 Event timer "HPET6" frequency 14318180 Hz quality 440 atrtc0: <AT realtime clock> port 0x70-0x77 irq 8 on acpi0 atrtc0: Warning: Couldn't map I/O. atrtc0: registered as a time-of-day clock, resolution 1.000000s Event timer "RTC" frequency 32768 Hz quality 0 attimer0: <AT timer> port 0x40-0x43,0x50-0x53 irq 0 on acpi0 Timecounter "i8254" frequency 1193182 Hz quality 0 Event timer "i8254" frequency 1193182 Hz quality 100 Timecounter "ACPI-fast" frequency 3579545 Hz quality 900 acpi_timer0: <24-bit timer at 3.579545MHz> port 0x408-0x40b on acpi0 tpm0: <Trusted Platform Module> iomem 0xfed40000-0xfed44fff on acpi0 tpm: device 0x0000104a rev 0x4e WARNING: Device "tpm" is Giant locked and may be deleted before FreeBSD 14.0. pcib0: <ACPI Host-PCI bridge> port 0xcf8-0xcff on acpi0 pci0: <ACPI PCI bus> on pcib0 pcib1: <ACPI PCI-PCI bridge> at device 1.0 on pci0 pci1: <ACPI PCI bus> on pcib1 mfi0: <Drake Skinny> port 0x2000-0x20ff mem 0xc1240000-0xc1243fff,0xc1200000-0xc123ffff irq 16 at device 0.0 on pci1 mfi0: Using MSI mfi0: Megaraid SAS driver Ver 4.23 mfi0: 82496 (722341165s/0x0020/info) - Shutdown command received from host mfip0: <SCSI Passthrough Bus>mfi0: 82497 (boot + 3s/0x0020/info) - Firmware initialization started (PCI ID 0073/1000/9241/1000) mfi0: 82498 (boot + 3s/0x0020/info) - Firmware version 2.130.404-4659 on mfi0 mfi0: 82499 (boot + 5s/0x0020/info) - Package version 20.13.1-0240 mfi0: 82500 (boot + 5s/0x0020/info) - Board Revision 03A mfi0: 82501 (boot + 25s/0x0002/info) - Inserted: PD 04(e0xff/s1) ehci0: <Intel Cougar Point USB 2.0 controller> mem 0xc1305000-0xc13053ff irq 20 at device 26.0 on pci0 usbus0: EHCI version 1.0 usbus0 on ehci0 pcib2: <ACPI PCI-PCI bridge> at device 28.0 on pci0 pci2: <ACPI PCI bus> on pcib2 pcib3: <ACPI PCI-PCI bridge> at device 28.4 on pci0 pci3: <ACPI PCI bus> on pcib3 bge0: <Broadcom NetXtreme Gigabit Ethernet Controller, ASIC rev. 0x00a200> mem 0xc1100000-0xc110ffff irq 16 at device 0.0 on pci3 bge0: CHIP ID 0x0000a200; ASIC REV 0x0a; CHIP REV 0xa2; PCI-E miibus0: <MII bus> on bge0 brgphy0: <BCM5722 1000BASE-T media interface> PHY 1 on miibus0 brgphy0: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseT, 1000baseT-master, 1000baseT-FDX, 1000baseT-FDX-master, auto, auto-flow bge0: Using defaults for TSO: 65518/35/2048 bge0: Ethernet address: [_MAC_XXXXXXXXXX] ehci1: <Intel Cougar Point USB 2.0 controller> mem 0xc1304000-0xc13043ff irq 23 at device 29.0 on pci0 usbus1: EHCI version 1.0 usbus1 on ehci1 pcib4: <ACPI PCI-PCI bridge> at device 30.0 on pci0 pci4: <ACPI PCI bus> on pcib4 vgapci0: <VGA-compatible display> mem 0xc0000000-0xc07fffff,0xc1000000-0xc1003fff,0xc0800000-0xc0ffffff irq 19 at device 3.0 on pci4 vgapci0: Boot video device isab0: <PCI-ISA bridge> at device 31.0 on pci0 isa0: <ISA bus> on isab0 ichsmb0: <Intel Cougar Point SMBus controller> port 0x3000-0x301f mem 0xc1302000-0xc13020ff irq 19 at device 31.3 on pci0 apei0: <ACPI Platform Error Interface> on acpi0 acpi_tz0: <Thermal Zone> on acpi0 ipmi0: <IPMI System Interface> port 0xca8,0xcac on acpi0 ipmi0: KCS mode found at io 0xca8 on acpi acpi_syscontainer0: <System Container> on acpi0 acpi_syscontainer1: <System Container> on acpi0 uart0: <16550 or compatible> port 0x3f8-0x3ff irq 4 flags 0x10 on acpi0 uart1: <16550 or compatible> port 0x2f8-0x2ff irq 3 on acpi0 orm0: <ISA Option ROMs> at iomem 0xc0000-0xc7fff,0xcf000-0xcffff,0xd0000-0xd0fff pnpid ORM0000 on isa0 coretemp0: <CPU On-Die Thermal Sensors> on cpu0 est0: <Enhanced SpeedStep Frequency Control> on cpu0 Timecounter "TSC-low" frequency 1446713562 Hz quality 1000 Timecounters tick every 1.000 msec usbus1: 480Mbps High Speed USB v2.0 mfi0: 82502 (boot + 25s/0x0002/info) - Inserted: PD 04(e0xff/s1) Info: enclPd=ffff, scsiType=0, portMap=00, sasAddr=44332211020usbus0: 480Mbps High Speed USB v2.0 00000,0000000000000000 ugen1.1: <Intel EHCI root HUB> at usbus1 mfid0 on mfi0 mfi0: 82503 (boot + 25s/0x0002/info) - Inserted: PD 05(e0xff/s0) mfid0: 1906394MB (3904294912 sectors) RAID volume 'FreeBSD11.0' is degraded smbus0: <System Management Bus> on ichsmb0 smb0: <SMBus generic I/O> on smbus0 ipmi0: IPMI device rev. 0, firmware rev. 1.95, version 2.0, device support mask 0xdf ipmi0: Number of channels 5 ipmi0: Attached watchdog ipmi0: Establishing power cycle handler uhub0 on usbus1 uhub0: <Intel EHCI root HUB, class 9/0, rev 2.00/1.00, addr 1> on usbus1 mfi0: 82504 (boot + 25s/0x0002/info) - Inserted: PD 05(e0xff/s0) Info: enclPd=ffff, scsiType=0, portMap=01, sasAddr=4433221103000000,0000000000000000 ugen0.1: <Intel EHCI root HUB> at usbus0 mfi0: 82505 (boot + 25s/0x0020/WARN) - PD missing: SasAddr=0x0, ArrayRef=0, RowIndex=0x1, EnclPd=0x40, Slot=0. mfi0: 82506 (722341209s/0x0020/info) - Time established as 11/21/22 10:20:09; (28 seconds since power on) mfi0: 82507 (722341245s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 0uhub11 00 mfi0: 82508 (722341245s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000 reset (Type 03) mfi0: 82509 (722341248s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 0 on usbus0 1 00 mfi0: 82510 (722341248s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000 reset (Type 03) mfi0: 82511 (722341252s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 01 00 mfi0: 82512 (722341252s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000 reset (Type 03) mfi0: 82513 (722341255s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 01 00 mfi0: 82514 (722341255s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000 reset (Type 03) mfi0: 82515 (722341258s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 0uhub1: <Intel EHCI root HUB, class 9/0, rev 2.00/1.00, addr 1> on usbus0 1 00 mfi0: 82516 (722341258s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000 reset (Type 03) mfi0: 82517 (722341261s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 01 00 mfi0: 82518 (722341261s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000 reset (Type 03) mfi0: 82519 (722341264s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 01 00 mfi0: 82520 (722341264s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000 reset (Type 03) mfi0: 82521 (722341267s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 01 00 mfi0: 82522 (722341267s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000 reset (Type 03) mfi0: 82523 (722341270s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 01 00 mfi0: 82524 (722341270s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000 reset (Type 03) mfi0: 82525 (722341273s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 01 00 mfi0: 82526 (722341273s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000 reset (Type 03) Trying to mount root from ufs:/dev/mfid0p2 [rw]... mfi0: 82527 (722341276s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 01 00 mfi0: 82528 (722341276s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000 reset (Type 03) mfi0: 82529 (722341279s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 01 00 mfi0: 82530 (722341279s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000 reset (Type 03) pass0 at mfi0 bus 0 scbus0 target 4 lun 0 pass0: <ATA WDC WD2002FAEX-0 1D05> Fixed Uninstalled SPC-3 SCSI device pass0: [_SERIAL_NUMBER_XXXXXXXXXXXX] pass0: 150.000MB/s transfers pass0: Command Queueing enabled pass1 at mfi0 bus 0 scbus0 target 5 lun 0 pass1: <ATA WDC WD2003FZEX-0 1A01> Fixed Uninstalled SPC-3 SCSI device pass1: [_SERIAL_NUMBER_XXXXXXXXXXXX] pass1: 150.000MB/s transfers pass1: Command Queueing enabled uhub0: 2 ports with 2 removable, self powered uhub1: 2 ports with 2 removable, self powered ugen0.2: <vendor 0x8087 product 0x0024> at usbus0 uhub2 on uhub1 uhub2: <vendor 0x8087 product 0x0024, class 9/0, rev 2.00/0.00, addr 2> on usbus0 ugen1.2: <vendor 0x8087 product 0x0024> at usbus1 uhub3 on uhub0 uhub3: <vendor 0x8087 product 0x0024, class 9/0, rev 2.00/0.00, addr 2> on usbus1 CPU: Intel(R) Pentium(R) CPU G645 @ 2.90GHz (2893.43-MHz K8-class CPU) Origin="GenuineIntel" Id=0x206a7 Family=0x6 Model=0x2a Stepping=7 Features=0xbfebfbff<FPU,VME,DE,PSE,TSC,MSR,PAE,MCE,CX8,APIC,SEP,MTRR,PGE,MCA,CMOV,PAT,PSE36,CLFLUSH,DTS,ACPI,MMX,FXSR,SSE,SSE2,SS,HTT,TM,PBE> Features2=0xd9ae3bf<SSE3,PCLMULQDQ,DTES64,MON,DS_CPL,VMX,EST,TM2,SSSE3,CX16,xTPR,PDCM,PCID,SSE4.1,SSE4.2,POPCNT,TSCDLT,XSAVE,OSXSAVE> AMD Features=0x28100800<SYSCALL,NX,RDTSCP,LM> AMD Features2=0x1<LAHF> Structured Extended Features3=0x9c000400<MD_CLEAR,IBPB,STIBP,L1DFL,SSBD> XSAVE Features=0x1<XSAVEOPT> VT-x: (disabled in BIOS) PAT,HLT,MTF,PAUSE,EPT,UG,VPID TSC: P-state invariant, performance statistics acpi_wmi0: <ACPI-WMI mapping> on acpi0 acpi_wmi0: cannot find EC device lo0: link state changed to UP uhub3: 6 ports with 6 removable, self powered uhub2: 6 ports with 6 removable, self powered bge0: link state changed to DOWN ugen1.3: <I-O DATA DEVICE. ETX3-US2> at usbus1 axe0 on uhub3 axe0: <0> on usbus1 miibus1: <MII bus> on axe0 ukphy0: <Generic IEEE 802.3u media interface> PHY 16 on miibus1 ukphy0: none, 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, auto ue0: <USB Ethernet> on axe0 ue0: Ethernet address: [_MAC_XXXXXXXXXX] bge0: link state changed to UP ue0: link state changed to DOWN