Launched in 2004, dmesgd aims to provide a user-submitted repository of searchable *BSD dmesgs. The dmesg(8) command displays the system message buffer's content, and during boot a copy is saved to /var/run/dmesg.boot. This buffer contains the operating system release, name and version, a list of devices identified, plus a whole host of other useful information. We hope others find this resource useful and further contribute to its growth. Contact us at [ admin at lists dot nycbug dot org ]. Note that this site is not a substitute for sending the dmesg directly to the respective project.
Date: 2026-07-16 16:52:31
From: Ken Wellsch
Description: NetBSD 11.99.7/sparc64 on SUNW,Sun-Fire-V215
[ 1.000000] Copyright (c) 1996, 1997, 1998, 1999, 2000, 2001, 2002, 2003,
[ 1.000000] 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013,
[ 1.000000] 2014, 2015, 2016, 2017, 2018, 2019, 2020, 2021, 2022, 2023,
[ 1.000000] 2024, 2025, 2026
[ 1.000000] The NetBSD Foundation, Inc. All rights reserved.
[ 1.000000] Copyright (c) 1982, 1986, 1989, 1991, 1993
[ 1.000000] The Regents of the University of California. All rights reserved.
[ 1.000000] NetBSD 11.99.7 (GENERIC) #0: Thu Jul 16 06:19:25 UTC 2026
[ 1.000000] [_EMAIL_XXXXXXXXXXXXXXXXX]:/usr/src/sys/arch/sparc64/compile/GENERIC
[ 1.000000] total memory = 16384 MB
[ 1.000000] avail memory = 16070 MB
[ 1.000000] timecounter: Timecounters tick every 10.000 msec
[ 1.000000] Kernelized RAIDframe activated
[ 1.000000] mainbus0 (root): SUNW,Sun-Fire-V215 (Sun Fire V215): [_HOSTID_XXXXX]
[ 1.000000] cpu0 at mainbus0: SUNW,UltraSPARC-IIIi @ 1504 MHz, CPU id 0
[ 1.000000] cpu0: manuf 3e, impl 16, mask 34
[ 1.000000] cpu0: system tick frequency 20 MHz
[ 1.000000] cpu0: 32K instruction (32 b/l), 64K data (32 b/l), 1024K external (64 b/l)
[ 1.000000] cpu1 at mainbus0: SUNW,UltraSPARC-IIIi @ 1504 MHz, CPU id 1
[ 1.000000] cpu1: manuf 3e, impl 16, mask 34
[ 1.000000] cpu1: system tick frequency 20 MHz
[ 1.000000] cpu1: 32K instruction (32 b/l), 64K data (32 b/l), 1024K external (64 b/l)
[ 1.000000] memory-controller at mainbus0 not configured
[ 1.000000] memory-controller at mainbus0 not configured
[ 1.000000] pyro0 at mainbus0: "Fire", rev 3, ign 780, bus A 2 to 14
[ 1.000000] pyro0: pci0 at pyro0
[ 1.000000] pci0: i/o space, memory space enabled
[ 1.000000] ppb0 at pci0 dev 0 function 0: PLX Technology product 8532 (rev. 0xbc)
[ 1.000000] ppb0: PCI Express capability version 1 <Upstream Port of PCI-E Switch>
[ 1.000000] pci1 at ppb0 bus 3
[ 1.000000] pci1: i/o space, memory space enabled
[ 1.000000] ppb1 at pci1 dev 1 function 0: PLX Technology product 8532 (rev. 0xbc)
[ 1.000000] ppb1: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x4 @ 2.5GT/s
[ 1.000000] pci2 at ppb1 bus 4
[ 1.000000] pci2: i/o space, memory space enabled
[ 1.000000] ppb2 at pci2 dev 0 function 0: Acer Labs M5249 Hypertransport to PCI Bridge (rev. 0x00)
[ 1.000000] ppb2: PCI Express capability version 1 <PCI-E to PCI/PCI-X Bridge>
[ 1.000000] pci3 at ppb2 bus 5
[ 1.000000] pci3: i/o space, memory space enabled
[ 1.000000] ohci0 at pci3 dev 28 function 0: Acer Labs M5237 USB 1.1 Host Controller (rev. 0x03)
[ 1.000000] ohci0: interrupting at ivec 780
[ 1.000000] ohci0: OHCI version 1.0, legacy support
[ 1.000000] usb0 at ohci0: USB revision 1.0
[ 1.000000] ohci1 at pci3 dev 28 function 1: Acer Labs M5237 USB 1.1 Host Controller (rev. 0x03)
[ 1.000000] ohci1: interrupting at ivec 780
[ 1.000000] ohci1: OHCI version 1.0, legacy support
[ 1.000000] usb1 at ohci1: USB revision 1.0
[ 1.000000] ehci0 at pci3 dev 28 function 3: Acer Labs M5239 USB 2.0 Host Controller (rev. 0x01)
[ 1.000000] ehci0: 32-bit DMA
[ 1.000000] ehci0: interrupting at ivec 781
[ 1.000000] ehci0: EHCI version 1.0
[ 1.000000] ehci0: wrong number of companions (3 != 2)
[ 1.000000] ehci0: 2 companion controllers, 3 ports each: ohci0 ohci1
[ 1.000000] usb2 at ehci0: USB revision 2.0
[ 1.000000] ebus0 at pci3 dev 30 function 0: Acer Labs product 1575, revision 0x00
[ 1.000000] rtc0 at ebus0 addr 70-73: mc146818 compatible time-of-day clock: m5823
[ 1.000000] aceride0 at pci3 dev 31 function 0: Acer Labs M5229 UDMA IDE Controller (rev. 0xc8)
[ 1.000000] aceride0: bus-master DMA support present
[ 1.000000] aceride0: primary channel configured to native-PCI mode
[ 1.000000] aceride0: using ivec 2f84 for native-PCI interrupt
[ 1.000000] atabus0 at aceride0 channel 0
[ 1.000000] aceride0: secondary channel configured to native-PCI mode
[ 1.000000] atabus1 at aceride0 channel 1
[ 1.000000] ppb3 at pci1 dev 2 function 0: PLX Technology product 8532 (rev. 0xbc)
[ 1.000000] ppb3: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x4 @ 2.5GT/s
[ 1.000000] pci4 at ppb3 bus 6
[ 1.000000] pci4: i/o space, memory space enabled
[ 1.000000] ppb4 at pci1 dev 8 function 0: PLX Technology product 8532 (rev. 0xbc)
[ 1.000000] ppb4: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x8 @ 2.5GT/s
[ 1.000000] pci5 at ppb4 bus 7
[ 1.000000] pci5: i/o space, memory space enabled
[ 1.000000] ppb5 at pci5 dev 0 function 0: PLX Technology PEX 8114 PCIe-to-PCI/PCI-X Bridge (rev. 0xbc)
[ 1.000000] ppb5: PCI Express capability version 1 <PCI-E to PCI/PCI-X Bridge>
[ 1.000000] pci6 at ppb5 bus 8
[ 1.000000] pci6: i/o space, memory space enabled
[ 1.000000] mpt0 at pci6 dev 8 function 0: Symbios Logic 53c1020/53c1030 (rev. 0x08)
[ 1.000000] mpt0: interrupting at ivec 2f94
[ 1.000000] scsibus0 at mpt0: 16 targets, 8 luns per target
[ 1.000000] mpt1 at pci6 dev 8 function 1: Symbios Logic 53c1020/53c1030 (rev. 0x08)
[ 1.000000] mpt1: interrupting at ivec 2f95
[ 1.000000] scsibus1 at mpt1: 16 targets, 8 luns per target
[ 1.000000] ppb6 at pci1 dev 9 function 0: PLX Technology product 8532 (rev. 0xbc)
[ 1.000000] ppb6: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x4 @ 2.5GT/s
[ 1.000000] pci7 at ppb6 bus 9
[ 1.000000] pci7: i/o space, memory space enabled
[ 1.000000] ppb7 at pci7 dev 0 function 0: ServerWorks BCM5714/BCM5715 Integral PCI-E to PCI-X Bridge (rev. 0xb5)
[ 1.000000] ppb7: PCI Express capability version 1 <PCI-E to PCI/PCI-X Bridge>
[ 1.000000] pci8 at ppb7 bus 10
[ 1.000000] pci8: i/o space, memory space enabled
[ 1.000000] bge0 at pci8 dev 4 function 0: Broadcom BCM5714 Gigabit Ethernet
[ 1.000000] bge0: interrupting at ivec 3795
[ 1.000000] bge0: HW config 00010115, 00000015, 00000000, 00000000 00000000
[ 1.000000] bge0: ASIC BCM5715 A3 (0x9003), Ethernet address [_MAC_XXXXXXXXXX]
[ 1.000000] bge0: autoconfiguration error: WARNING: failed to restrict dma range, falling back to parent bus dma range
[ 1.000000] bge0: setting short Tx thresholds
[ 1.000000] brgphy0 at bge0 phy 1: BCM5714 1000BASE-T/X media interface, rev. 0
[ 1.000000] brgphy0: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseT, 1000baseT-FDX, auto
[ 1.000000] bge1 at pci8 dev 4 function 1: Broadcom BCM5714 Gigabit Ethernet
[ 1.000000] bge1: interrupting at ivec 3796
[ 1.000000] bge1: HW config 00000114, 00000014, 00000000, 00000000 00000000
[ 1.000000] bge1: ASIC BCM5715 A3 (0x9003), Ethernet address [_MAC_XXXXXXXXXX]
[ 1.000000] bge1: autoconfiguration error: WARNING: failed to restrict dma range, falling back to parent bus dma range
[ 1.000000] bge1: setting short Tx thresholds
[ 1.000000] brgphy1 at bge1 phy 1: BCM5714 1000BASE-T/X media interface, rev. 0
[ 1.000000] brgphy1: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseT, 1000baseT-FDX, auto
[ 1.000000] ppb8 at pci8 dev 8 function 0: ServerWorks HT1000 PCI/PCI-X Bridge (rev. 0xb4)
[ 1.000000] pci9 at ppb8 bus 11
[ 1.000000] pci9: i/o space, memory space enabled
[ 1.000000] ppb9 at pci1 dev 10 function 0: PLX Technology product 8532 (rev. 0xbc)
[ 1.000000] ppb9: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x4 @ 2.5GT/s
[ 1.000000] pci10 at ppb9 bus 12
[ 1.000000] pci10: i/o space, memory space enabled
[ 1.000000] ppb10 at pci10 dev 0 function 0: ServerWorks BCM5714/BCM5715 Integral PCI-E to PCI-X Bridge (rev. 0xb5)
[ 1.000000] ppb10: PCI Express capability version 1 <PCI-E to PCI/PCI-X Bridge>
[ 1.000000] pci11 at ppb10 bus 13
[ 1.000000] pci11: i/o space, memory space enabled
[ 1.000000] bge2 at pci11 dev 4 function 0: Broadcom BCM5714 Gigabit Ethernet
[ 1.000000] bge2: interrupting at ivec 3796
[ 1.000000] bge2: HW config 00010115, 00000015, 00000000, 00000000 00000000
[ 1.000000] bge2: ASIC BCM5715 A3 (0x9003), Ethernet address [_MAC_XXXXXXXXXX]
[ 1.000000] bge2: autoconfiguration error: WARNING: failed to restrict dma range, falling back to parent bus dma range
[ 1.000000] bge2: setting short Tx thresholds
[ 1.000000] brgphy2 at bge2 phy 1: BCM5714 1000BASE-T/X media interface, rev. 0
[ 1.000000] brgphy2: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseT, 1000baseT-FDX, auto
[ 1.000000] bge3 at pci11 dev 4 function 1: Broadcom BCM5714 Gigabit Ethernet
[ 1.000000] bge3: interrupting at ivec 3797
[ 1.000000] bge3: HW config 00000114, 00000014, 00000000, 00000000 00000000
[ 1.000000] bge3: ASIC BCM5715 A3 (0x9003), Ethernet address [_MAC_XXXXXXXXXX]
[ 1.000000] bge3: autoconfiguration error: WARNING: failed to restrict dma range, falling back to parent bus dma range
[ 1.000000] bge3: setting short Tx thresholds
[ 1.000000] brgphy3 at bge3 phy 1: BCM5714 1000BASE-T/X media interface, rev. 0
[ 1.000000] brgphy3: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseT, 1000baseT-FDX, auto
[ 1.000000] ppb11 at pci11 dev 8 function 0: ServerWorks HT1000 PCI/PCI-X Bridge (rev. 0xb4)
[ 1.000000] pci12 at ppb11 bus 14
[ 1.000000] pci12: i/o space, memory space enabled
[ 1.000000] mpt2 at pci12 dev 1 function 0: Symbios Logic SAS1064 (rev. 0x02)
[ 1.000000] mpt2: interrupting at ivec 2f8f
[ 1.000000] mpt2: Phy 0: Link Status Unknown
[ 1.000000] scsibus2 at mpt2: 63 targets, 8 luns per target
[ 1.000000] pyro1 at mainbus0: "Fire", rev 3, ign 7c0, bus B 2 to 255
[ 1.000000] pyro1: pci13 at pyro1
[ 1.000000] pci13: i/o space, memory space enabled
[ 1.000000] ebus1 at mainbus0
[ 1.000000] flashprom at ebus1 addr 0-1fffff not configured
[ 1.000000] com0 at ebus1 addr 80-87 ipl 7c8: ns16550a, 16-byte FIFO
[ 1.000000] com0: console
[ 1.000000] com1 at ebus1 addr 40-47 ipl 7c9: ns16550a, 16-byte FIFO
[ 1.000000] rmc-comm at ebus1 addr 0-7 ipl 7ca not configured
[ 1.000000] gpio at ebus1 addr c0-c0 not configured
[ 1.000000] env-monitor at ebus1 addr 0-80 not configured
[ 1.000000] power at ebus1 addr 40-c1 ipl 7c3 not configured
[ 1.000000] firei2c0 at mainbus0: addr 4000fd30000: Fire/MI2C i2c controller
[ 1.000000] iic0 at firei2c0: I2C bus
[ 1.000000] seeprom0 at iic0 addr 0x19: pdb-fru-prom: size 8192
[ 1.000000] seeprom1 at iic0 addr 0x32: sasbp-fru-prom: size 8192
[ 1.000000] seeprom2 at iic0 addr 0x36: power-supply-fru-prom: size 256
[ 1.000000] seeprom3 at iic0 addr 0x37: power-supply-fru-prom: size 256
[ 1.000000] pcf8574io0 at iic0 addr 0x3e: GPIO
[ 1.000000] pcf8574io1 at iic0 addr 0x3f: GPIO
[ 1.000000] pcagpio0 at iic0 addr 0x40: PCA9555
[ 1.000000] seeprom4 at iic0 addr 0x51: motherboard-fru-prom: size 8192
[ 1.000000] seeprom5 at iic0 addr 0x53: nvram: size 8192
[ 1.000000] seeprom6 at iic0 addr 0x54: riser-fru-prom: size 8192
[ 1.000000] seeprom7 at iic0 addr 0x55: riser-fru-prom: size 8192
[ 1.000000] adt7462sm0 at iic0 addr 0x58: ADT7462 system monitor: rev. 0x4
[ 1.000000] adt7462sm0: 3 fans, 4 temperatures, 5 voltages
[ 1.000000] rscrtc (i2c-ds1307) at iic0 addr 0x68 not configured
[ 1.000000] clock-generator (i2c-ics9fg108) at iic0 addr 0x6e not configured
[ 1.000000] spdmem0 at iic0 addr 0x70
[ 1.000000] spdmem0: DDR SDRAM (registered), data ECC, 2GB, 400MHz (PC-3200)
[ 1.000000] spdmem0: 13 rows, 12 cols, 2 ranks, 4 banks/chip, 5.0ns cycle time
[ 1.000000] spdmem0: tAA-tRCD-tRP-tRAS: 2-3-3-8
[ 1.000000] spdmem0: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] spdmem1 at iic0 addr 0x71
[ 1.000000] spdmem1: DDR SDRAM (registered), data ECC, 2GB, 400MHz (PC-3200)
[ 1.000000] spdmem1: 13 rows, 12 cols, 2 ranks, 4 banks/chip, 5.0ns cycle time
[ 1.000000] spdmem1: tAA-tRCD-tRP-tRAS: 2-3-3-8
[ 1.000000] spdmem1: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] spdmem2 at iic0 addr 0x72
[ 1.000000] spdmem2: DDR SDRAM (registered), data ECC, 2GB, 400MHz (PC-3200)
[ 1.000000] spdmem2: 13 rows, 12 cols, 2 ranks, 4 banks/chip, 5.0ns cycle time
[ 1.000000] spdmem2: tAA-tRCD-tRP-tRAS: 2-3-3-8
[ 1.000000] spdmem2: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] spdmem3 at iic0 addr 0x73
[ 1.000000] spdmem3: DDR SDRAM (registered), data ECC, 2GB, 400MHz (PC-3200)
[ 1.000000] spdmem3: 13 rows, 12 cols, 2 ranks, 4 banks/chip, 5.0ns cycle time
[ 1.000000] spdmem3: tAA-tRCD-tRP-tRAS: 2-3-3-8
[ 1.000000] spdmem3: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] spdmem4 at iic0 addr 0x74
[ 1.000000] spdmem4: DDR SDRAM (registered), data ECC, 2GB, 400MHz (PC-3200)
[ 1.000000] spdmem4: 13 rows, 12 cols, 2 ranks, 4 banks/chip, 5.0ns cycle time
[ 1.000000] spdmem4: tAA-tRCD-tRP-tRAS: 2-3-3-8
[ 1.000000] spdmem4: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] spdmem5 at iic0 addr 0x75
[ 1.000000] spdmem5: DDR SDRAM (registered), data ECC, 2GB, 400MHz (PC-3200)
[ 1.000000] spdmem5: 13 rows, 12 cols, 2 ranks, 4 banks/chip, 5.0ns cycle time
[ 1.000000] spdmem5: tAA-tRCD-tRP-tRAS: 2-3-3-8
[ 1.000000] spdmem5: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] spdmem6 at iic0 addr 0x76
[ 1.000000] spdmem6: DDR SDRAM (registered), data ECC, 2GB, 400MHz (PC-3200)
[ 1.000000] spdmem6: 13 rows, 12 cols, 2 ranks, 4 banks/chip, 5.0ns cycle time
[ 1.000000] spdmem6: tAA-tRCD-tRP-tRAS: 2-3-3-8
[ 1.000000] spdmem6: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] spdmem7 at iic0 addr 0x77
[ 1.000000] spdmem7: DDR SDRAM (registered), data ECC, 2GB, 400MHz (PC-3200)
[ 1.000000] spdmem7: 13 rows, 12 cols, 2 ranks, 4 banks/chip, 5.0ns cycle time
[ 1.000000] spdmem7: tAA-tRCD-tRP-tRAS: 2-3-3-8
[ 1.000000] spdmem7: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] pcagpio1 at iic0 addr 0x22: PCA9555
[ 1.000000] lm95221ts0 at iic0 addr 0x2b: LM95221 temperature sensor
[ 1.000000] dbcool0 at iic0 addr 0x2e
[ 1.000000] dbcool0: ADT7475 dBCool(tm) Controller (rev 0x0069)
[ 1.000000] pcons at mainbus0 not configured
[ 1.000000] WARNING: system needs entropy for security; see entropy(7)
[ 1.000000] timecounter: Timecounter "tick-counter" frequency 1504000000 Hz quality 100
[ 1.000003] timecounter: Timecounter "stick-counter" frequency 20000000 Hz quality 200
[ 1.000016] No counter-timer -- using %stick at 20MHz as system clock.
[ 1.000016] timecounter: Timecounter "clockinterrupt" frequency 100 Hz quality 0
[ 2.748379] uhub0 at usb0: NetBSD (0x0000) OHCI root hub (0x0000), class 9/0, rev 1.00/1.00, addr 1
[ 2.748379] uhub0: 3 ports with 3 removable, self powered
[ 2.748379] uhub1 at usb1: NetBSD (0x0000) OHCI root hub (0x0000), class 9/0, rev 1.00/1.00, addr 1
[ 2.748379] uhub1: 3 ports with 3 removable, self powered
[ 2.748379] uhub2 at usb2: NetBSD (0x0000) EHCI root hub (0x0000), class 9/0, rev 2.00/1.00, addr 1
[ 2.748379] uhub2: 8 ports with 8 removable, self powered
[ 2.748379] scsibus0: waiting 2 seconds for devices to settle...
[ 2.748379] scsibus1: waiting 2 seconds for devices to settle...
[ 2.748379] scsibus2: waiting 2 seconds for devices to settle...
[ 4.804714] sd0 at scsibus0 target 0 lun 0: <ZULUSCSI, HARDDRIVE, 2.3W> disk fixed
[ 4.895123] sd0: 4095 MB, 8320 cyl, 16 head, 63 sec, 512 bytes/sect x 8386560 sectors
[ 4.994715] sd0: sync (50.00ns offset 15), 16-bit (40.000MB/s) transfers
[ 7.084715] cd0 at scsibus0 target 5 lun 0: <ZULUSCSI, CDROM, 2.3W> cdrom removable
[ 7.184715] cd0: sync (50.00ns offset 15), 16-bit (40.000MB/s) transfers
[ 19.274713] sd1 at scsibus2 target 0 lun 0: <HITACHI, H101473SCSUN72G, SA23> disk fixed
[ 19.370699] sd1: 70007 MB, 14089 cyl, 24 head, 424 sec, 512 bytes/sect x 143374738 sectors
[ 19.474713] sd1: 25426 trailing sectors not covered by disklabel
[ 19.550072] sd1: tagged queueing
[ 19.604714] swwdog0: software watchdog initialized
[ 19.664714] sd1: 25426 trailing sectors not covered by disklabel
[ 19.734713] sd1: 25426 trailing sectors not covered by disklabel
[ 19.804713] WARNING: 4 errors while detecting hardware; check system log.
[ 19.884713] root on sd0a dumps on sd0b
[ 19.934713] root file system type: ffs
[ 19.974713] kern.module.path=/stand/sparc64/11.99.7/modules
[ 20.124714] entropy: best effort
[ 21.094718] entropy: ready
[ 33.424715] adt7462sm0: warning under limit on 'fan 4'
[ 33.504714] adt7462sm0: warning under limit on 'fan 6'
[ 33.584714] adt7462sm0: warning under limit on 'fan 7'
[ 33.664714] adt7462sm0: warning under limit on 'local'
[ 33.744713] adt7462sm0: warning under limit on 'remote 1'
[ 33.814713] adt7462sm0: warning under limit on 'remote 2'
[ 33.894713] adt7462sm0: warning under limit on 'remote 3'
[ 213.554669] adt7462sm0: normal state on 'local'
[ 213.674669] adt7462sm0: normal state on 'remote 2'
[ 243.574669] adt7462sm0: warning under limit on 'local'
[ 243.724669] adt7462sm0: warning under limit on 'remote 2'
netra240$ envstat
Current CritMax WarnMax WarnMin CritMin Unit
[adt7462sm0]
fan 4: 0 82 RPM
fan 6: 0 82 RPM
fan 7: 0 82 RPM
local: 44.750 85.000 65.000 45.000 degC
remote 1: 47.250 71.000 61.000 51.000 degC
remote 2: 50.750 71.000 61.000 51.000 degC
remote 3: 50.250 100.000 95.000 65.000 degC
V1.5 1: 1.451 1.989 0.250 V
V1.5 2: 1.466 1.989 V
V3.3 1: 3.302 4.386 V
Vbatt: 3.042 3.978 1.997 V
V12 2: 12.062 15.938 V
fan fault: 0 0 0 0 0 none
[dbcool0]
l_temp: 35.000 degC
r1_temp: 31.250 degC
r2_temp: 31.500 degC
Vccp: N/A
Vcc: 3.343 V
fan1: 20224 RPM
fan2: 21774 RPM
fan3: N/A
fan4: N/A
[lm95221ts0]
local: 43.500 degC
remote 1: 39.375 degC
remote 2: 67.250 degC