Launched in 2004, dmesgd aims to provide a user-submitted repository of searchable *BSD dmesgs. The dmesg(8) command displays the system message buffer's content, and during boot a copy is saved to /var/run/dmesg.boot. This buffer contains the operating system release, name and version, a list of devices identified, plus a whole host of other useful information. We hope others find this resource useful and further contribute to its growth. Contact us at [ admin at lists dot nycbug dot org ]. Note that this site is not a substitute for sending the dmesg directly to the respective project.
Date: 2026-09-19 14:54:56
From: Ken Wellsch
Description: NetBSD 11.99.8 on SUNW,Sun-Fire-V445
[ 1.000000] Copyright (c) 1996, 1997, 1998, 1999, 2000, 2001, 2002, 2003,
[ 1.000000] 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013,
[ 1.000000] 2014, 2015, 2016, 2017, 2018, 2019, 2020, 2021, 2022, 2023,
[ 1.000000] 2024, 2025, 2026
[ 1.000000] The NetBSD Foundation, Inc. All rights reserved.
[ 1.000000] Copyright (c) 1982, 1986, 1989, 1991, 1993
[ 1.000000] The Regents of the University of California. All rights reserved.
[ 1.000000] NetBSD 11.99.8 (GENERIC) #0: Sat Sep 19 02:45:29 UTC 2026
[ 1.000000] [_EMAIL_XXXXXXXXXXXXXXXXX]:/usr/src/sys/arch/sparc64/compile/GENERIC
[ 1.000000] total memory = 16384 MB
[ 1.000000] avail memory = 16070 MB
[ 1.000000] timecounter: Timecounters tick every 10.000 msec
[ 1.000000] Kernelized RAIDframe activated
[ 1.000000] mainbus0 (root): SUNW,Sun-Fire-V445 (Sun Fire V445): [_HOSTID_XXXXX]
[ 1.000000] cpu0 at mainbus0: SUNW,UltraSPARC-IIIi @ 1593 MHz, CPU id 0
[ 1.000000] cpu0: manuf 3e, impl 16, mask 34
[ 1.000000] cpu0: system tick frequency 10 MHz
[ 1.000000] cpu0: 32K instruction (32 b/l), 64K data (32 b/l), 1024K external (64 b/l)
[ 1.000000] cpu1 at mainbus0: SUNW,UltraSPARC-IIIi @ 1593 MHz, CPU id 1
[ 1.000000] cpu1: manuf 3e, impl 16, mask 34
[ 1.000000] cpu1: system tick frequency 10 MHz
[ 1.000000] cpu1: 32K instruction (32 b/l), 64K data (32 b/l), 1024K external (64 b/l)
[ 1.000000] cpu2 at mainbus0: SUNW,UltraSPARC-IIIi @ 1593 MHz, CPU id 2
[ 1.000000] cpu2: manuf 3e, impl 16, mask 34
[ 1.000000] cpu2: system tick frequency 10 MHz
[ 1.000000] cpu2: 32K instruction (32 b/l), 64K data (32 b/l), 1024K external (64 b/l)
[ 1.000000] cpu3 at mainbus0: SUNW,UltraSPARC-IIIi @ 1593 MHz, CPU id 3
[ 1.000000] cpu3: manuf 3e, impl 16, mask 34
[ 1.000000] cpu3: system tick frequency 10 MHz
[ 1.000000] cpu3: 32K instruction (32 b/l), 64K data (32 b/l), 1024K external (64 b/l)
[ 1.000000] memory-controller at mainbus0 not configured
[ 1.000000] memory-controller at mainbus0 not configured
[ 1.000000] memory-controller at mainbus0 not configured
[ 1.000000] memory-controller at mainbus0 not configured
[ 1.000000] pyro0 at mainbus0: "Fire", rev 3, ign 780, bus A 2 to 10
[ 1.000000] pyro0: pci0 at pyro0
[ 1.000000] pci0: i/o space, memory space enabled
[ 1.000000] ppb0 at pci0 dev 0 function 0: PLX Technology product 8532 (rev. 0xba)
[ 1.000000] ppb0: PCI Express capability version 1 <Upstream Port of PCI-E Switch>
[ 1.000000] pci1 at ppb0 bus 3
[ 1.000000] pci1: i/o space, memory space enabled
[ 1.000000] ppb1 at pci1 dev 1 function 0: PLX Technology product 8532 (rev. 0x03)
[ 1.000000] ppb1: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x4 @ 2.5GT/s
[ 1.000000] pci2 at ppb1 bus 4
[ 1.000000] pci2: i/o space, memory space enabled
[ 1.000000] ppb2 at pci2 dev 0 function 0: ServerWorks BCM5714/BCM5715 Integral PCI-E to PCI-X Bridge (rev. 0xb5)
[ 1.000000] ppb2: PCI Express capability version 1 <PCI-E to PCI/PCI-X Bridge>
[ 1.000000] pci3 at ppb2 bus 5
[ 1.000000] pci3: i/o space, memory space enabled
[ 1.000000] bge0 at pci3 dev 4 function 0: Broadcom BCM5714 Gigabit Ethernet
[ 1.000000] bge0: interrupting at ivec 3795
[ 1.000000] bge0: HW config 00000015, 00000015, 00000000, 00000000 00000000
[ 1.000000] bge0: ASIC BCM5715 A3 (0x9003), Ethernet address [_MAC_XXXXXXXXXX]
[ 1.000000] bge0: autoconfiguration error: WARNING: failed to restrict dma range, falling back to parent bus dma range
[ 1.000000] bge0: setting short Tx thresholds
[ 1.000000] brgphy0 at bge0 phy 1: BCM5714 1000BASE-T/X media interface, rev. 0
[ 1.000000] brgphy0: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseT, 1000baseT-FDX, auto
[ 1.000000] bge1 at pci3 dev 4 function 1: Broadcom BCM5714 Gigabit Ethernet
[ 1.000000] bge1: interrupting at ivec 3796
[ 1.000000] bge1: HW config 00000014, 00000014, 00000000, 00000000 00000000
[ 1.000000] bge1: ASIC BCM5715 A3 (0x9003), Ethernet address [_MAC_XXXXXXXXXX]
[ 1.000000] bge1: autoconfiguration error: WARNING: failed to restrict dma range, falling back to parent bus dma range
[ 1.000000] bge1: setting short Tx thresholds
[ 1.000000] brgphy1 at bge1 phy 1: BCM5714 1000BASE-T/X media interface, rev. 0
[ 1.000000] brgphy1: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseT, 1000baseT-FDX, auto
[ 1.000000] ppb3 at pci3 dev 8 function 0: ServerWorks HT1000 PCI/PCI-X Bridge (rev. 0xb4)
[ 1.000000] pci4 at ppb3 bus 6
[ 1.000000] pci4: i/o space, memory space enabled
[ 1.000000] ppb4 at pci4 dev 1 function 0: Intel S21152BA,S21154AE/BE PCI-PCI Bridge (rev. 0x00)
[ 1.000000] pci5 at ppb4 bus 7
[ 1.000000] pci5: i/o space, memory space enabled
[ 1.000000] cas0 at pci5 dev 0 function 0: National Semiconductor Saturn (rev. 0x30)
[ 1.000000] cas0: interrupting at ivec 3780
[ 1.000000] cas0: Ethernet address [_MAC_XXXXXXXXXX]
[ 1.000000] gphyter0 at cas0 phy 1: DP83865 1000BASE-T media interface, rev. 8
[ 1.000000] gphyter0: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseT, 1000baseT-FDX, auto
[ 1.000000] gphyter0: strapped to slave mode
[ 1.000000] cas1 at pci5 dev 1 function 0: National Semiconductor Saturn (rev. 0x30)
[ 1.000000] cas1: interrupting at ivec 3781
[ 1.000000] cas1: Ethernet address [_MAC_XXXXXXXXXX]
[ 1.000000] gphyter1 at cas1 phy 1: DP83865 1000BASE-T media interface, rev. 8
[ 1.000000] gphyter1: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseT, 1000baseT-FDX, auto
[ 1.000000] gphyter1: strapped to slave mode
[ 1.000000] esiop0 at pci5 dev 2 function 0: Symbios Logic 53c896 (ultra2-wide scsi)
[ 1.000000] esiop0: using on-board RAM
[ 1.000000] esiop0: interrupting at ivec 2f82
[ 1.000000] scsibus0 at esiop0: 16 targets, 8 luns per target
[ 1.000000] esiop1 at pci5 dev 2 function 1: Symbios Logic 53c896 (ultra2-wide scsi)
[ 1.000000] esiop1: using on-board RAM
[ 1.000000] esiop1: interrupting at ivec 2f83
[ 1.000000] scsibus1 at esiop1: 16 targets, 8 luns per target
[ 1.000000] ppb5 at pci1 dev 2 function 0: PLX Technology product 8532 (rev. 0x0a)
[ 1.000000] ppb5: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x4 @ 2.5GT/s
[ 1.000000] pci6 at ppb5 bus 8
[ 1.000000] pci6: i/o space, memory space enabled
[ 1.000000] mpt0 at pci6 dev 0 function 0: Symbios Logic SAS1068E (rev. 0x02)
[ 1.000000] mpt0: interrupting at ivec 2f96
[ 1.000000] mpt0: Phy 0: Link Status Unknown
[ 1.000000] scsibus2 at mpt0: 112 targets, 8 luns per target
[ 1.000000] ppb6 at pci1 dev 8 function 0: PLX Technology product 8532 (rev. 0xba)
[ 1.000000] ppb6: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x8 @ 2.5GT/s
[ 1.000000] pci7 at ppb6 bus 9
[ 1.000000] pci7: i/o space, memory space enabled
[ 1.000000] ppb7 at pci1 dev 9 function 0: PLX Technology product 8532 (rev. 0xba)
[ 1.000000] ppb7: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x8 @ 2.5GT/s
[ 1.000000] pci8 at ppb7 bus 10
[ 1.000000] pci8: i/o space, memory space enabled
[ 1.000000] pyro1 at mainbus0: "Fire", rev 3, ign 7c0, bus B 2 to 10
[ 1.000000] pyro1: pci9 at pyro1
[ 1.000000] pci9: i/o space, memory space enabled
[ 1.000000] ppb8 at pci9 dev 0 function 0: PLX Technology product 8532 (rev. 0xba)
[ 1.000000] ppb8: PCI Express capability version 1 <Upstream Port of PCI-E Switch>
[ 1.000000] pci10 at ppb8 bus 3
[ 1.000000] pci10: i/o space, memory space enabled
[ 1.000000] ppb9 at pci10 dev 1 function 0: PLX Technology product 8532 (rev. 0x03)
[ 1.000000] ppb9: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x4 @ 2.5GT/s
[ 1.000000] pci11 at ppb9 bus 4
[ 1.000000] pci11: i/o space, memory space enabled
[ 1.000000] ppb10 at pci11 dev 0 function 0: Acer Labs M5249 Hypertransport to PCI Bridge (rev. 0x00)
[ 1.000000] ppb10: PCI Express capability version 1 <PCI-E to PCI/PCI-X Bridge>
[ 1.000000] pci12 at ppb10 bus 5
[ 1.000000] pci12: i/o space, memory space enabled
[ 1.000000] ohci0 at pci12 dev 28 function 0: Acer Labs M5237 USB 1.1 Host Controller (rev. 0x03)
[ 1.000000] ohci0: interrupting at ivec 7ca
[ 1.000000] ohci0: OHCI version 1.0, legacy support
[ 1.000000] usb0 at ohci0: USB revision 1.0
[ 1.000000] ohci1 at pci12 dev 28 function 1: Acer Labs M5237 USB 1.1 Host Controller (rev. 0x03)
[ 1.000000] ohci1: interrupting at ivec 7ca
[ 1.000000] ohci1: OHCI version 1.0, legacy support
[ 1.000000] usb1 at ohci1: USB revision 1.0
[ 1.000000] ohci2 at pci12 dev 28 function 2: Acer Labs M5237 USB 1.1 Host Controller (rev. 0x03)
[ 1.000000] ohci2: interrupting at ivec 7ca
[ 1.000000] ohci2: OHCI version 1.0, legacy support
[ 1.000000] ohci2: Clear PME# now
[ 1.000000] usb2 at ohci2: USB revision 1.0
[ 1.000000] ehci0 at pci12 dev 28 function 3: Acer Labs M5239 USB 2.0 Host Controller (rev. 0x01)
[ 1.000000] ehci0: 32-bit DMA
[ 1.000000] ehci0: interrupting at ivec 7c9
[ 1.000000] ehci0: EHCI version 1.0
[ 1.000000] ehci0: 3 companion controllers, 3 ports each: ohci0 ohci1 ohci2
[ 1.000000] usb3 at ehci0: USB revision 2.0
[ 1.000000] ebus0 at pci12 dev 30 function 0: Acer Labs product 1575, revision 0x00
[ 1.000000] rtc0 at ebus0 addr 70-73: mc146818 compatible time-of-day clock: m5823
[ 1.000000] aceride0 at pci12 dev 31 function 0: Acer Labs M5229 UDMA IDE Controller (rev. 0xc8)
[ 1.000000] aceride0: bus-master DMA support present
[ 1.000000] aceride0: primary channel configured to native-PCI mode
[ 1.000000] aceride0: using ivec 2fc8 for native-PCI interrupt
[ 1.000000] atabus0 at aceride0 channel 0
[ 1.000000] aceride0: secondary channel configured to native-PCI mode
[ 1.000000] atabus1 at aceride0 channel 1
[ 1.000000] ppb11 at pci10 dev 2 function 0: PLX Technology product 8532 (rev. 0x0b)
[ 1.000000] ppb11: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x4 @ 2.5GT/s
[ 1.000000] pci13 at ppb11 bus 6
[ 1.000000] pci13: i/o space, memory space enabled
[ 1.000000] ppb12 at pci13 dev 0 function 0: ServerWorks BCM5714/BCM5715 Integral PCI-E to PCI-X Bridge (rev. 0xb5)
[ 1.000000] ppb12: PCI Express capability version 1 <PCI-E to PCI/PCI-X Bridge>
[ 1.000000] pci14 at ppb12 bus 7
[ 1.000000] pci14: i/o space, memory space enabled
[ 1.000000] bge2 at pci14 dev 4 function 0: Broadcom BCM5714 Gigabit Ethernet
[ 1.000000] bge2: interrupting at ivec 37d6
[ 1.000000] bge2: HW config 00000015, 00000015, 00000000, 00000000 00000000
[ 1.000000] bge2: ASIC BCM5715 A3 (0x9003), Ethernet address [_MAC_XXXXXXXXXX]
[ 1.000000] bge2: autoconfiguration error: WARNING: failed to restrict dma range, falling back to parent bus dma range
[ 1.000000] bge2: setting short Tx thresholds
[ 1.000000] brgphy2 at bge2 phy 1: BCM5714 1000BASE-T/X media interface, rev. 0
[ 1.000000] brgphy2: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseT, 1000baseT-FDX, auto
[ 1.000000] bge3 at pci14 dev 4 function 1: Broadcom BCM5714 Gigabit Ethernet
[ 1.000000] bge3: interrupting at ivec 37d7
[ 1.000000] bge3: HW config 00000014, 00000014, 00000000, 00000000 00000000
[ 1.000000] bge3: ASIC BCM5715 A3 (0x9003), Ethernet address [_MAC_XXXXXXXXXX]
[ 1.000000] bge3: autoconfiguration error: WARNING: failed to restrict dma range, falling back to parent bus dma range
[ 1.000000] bge3: setting short Tx thresholds
[ 1.000000] brgphy3 at bge3 phy 1: BCM5714 1000BASE-T/X media interface, rev. 0
[ 1.000000] brgphy3: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseT, 1000baseT-FDX, auto
[ 1.000000] ppb13 at pci14 dev 8 function 0: ServerWorks HT1000 PCI/PCI-X Bridge (rev. 0xb4)
[ 1.000000] pci15 at ppb13 bus 8
[ 1.000000] pci15: i/o space, memory space enabled
[ 1.000000] ppb14 at pci10 dev 8 function 0: PLX Technology product 8532 (rev. 0xba)
[ 1.000000] ppb14: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x8 @ 2.5GT/s
[ 1.000000] pci16 at ppb14 bus 9
[ 1.000000] pci16: i/o space, memory space enabled
[ 1.000000] ppb15 at pci10 dev 9 function 0: PLX Technology product 8532 (rev. 0xba)
[ 1.000000] ppb15: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x8 @ 2.5GT/s
[ 1.000000] pci17 at ppb15 bus 10
[ 1.000000] pci17: i/o space, memory space enabled
[ 1.000000] ebus1 at mainbus0
[ 1.000000] flashprom at ebus1 addr 0-1fffff not configured
[ 1.000000] gpio at ebus1 addr c00008-c00008 not configured
[ 1.000000] power at ebus1 addr c0a100-c0a12f ipl 786 not configured
[ 1.000000] rmc-comm at ebus1 addr c28000-c28007 ipl 789 not configured
[ 1.000000] com0 at ebus1 addr c2c000-c2c007 ipl 787: ns16550a, 16-byte FIFO
[ 1.000000] com0: console
[ 1.000000] com1 at ebus1 addr fffff8-ffffff ipl 78a: ns16550a, 16-byte FIFO
[ 1.000000] firei2c0 at mainbus0: addr 4000fd20000: Fire/MI2C i2c controller
[ 1.000000] iic0 at firei2c0: I2C bus
[ 1.000000] admtemp0 at iic0 addr 0x08: MAX1617A temperature sensor: id. 0x4d, rev. 0x01
[ 1.000000] i2c-bridge (SUNW,i2c-imax) at iic0 addr 0x09 not configured
[ 1.000000] i2c-bridge (SUNW,i2c-imax) at iic0 addr 0x0b not configured
[ 1.000000] i2c-bridge (SUNW,i2c-imax) at iic0 addr 0x0c not configured
[ 1.000000] i2c-bridge (SUNW,i2c-imax) at iic0 addr 0x0d not configured
[ 1.000000] spdmem0 at iic0 addr 0x12
[ 1.000000] spdmem0: FPM
[ 1.000000] spdmem0: 0 rows, 0 cols, 0 banks, 0ns tRAC, 0ns tCAC
[ 1.000000] lmtemp0 at iic0 addr 0x13: temperature-sensor LM75 Temperature Sensor
[ 1.000000] admtemp1 at iic0 addr 0x18: MAX1617A temperature sensor: id. 0xff, rev. 0xff
[ 1.000000] spdmem1 at iic0 addr 0x19
[ 1.000000] spdmem1: FPM
[ 1.000000] spdmem1: 0 rows, 0 cols, 0 banks, 0ns tRAC, 0ns tCAC
[ 1.000000] pcagpio0 at iic0 addr 0x1c: PCA9555
[ 1.000000] pcagpio1 at iic0 addr 0x1d: PCA9555
[ 1.000000] pcagpio2 at iic0 addr 0x1e: PCA9555
[ 1.000000] pcagpio3 at iic0 addr 0x20: PCA9555
[ 1.000000] seeprom0 at iic0 addr 0x23: sas-ctrl-fru-prom: size 8192
[ 1.000000] seeprom1 at iic0 addr 0x24: sas-backplane-fru-prom: size 8192
[ 1.000000] seeprom2 at iic0 addr 0x27: front-io-fru-prom: size 8192
[ 1.000000] admtemp2 at iic0 addr 0x28: MAX1617A temperature sensor: id. 0xff, rev. 0xff
[ 1.000000] spdmem2 at iic0 addr 0x29
[ 1.000000] spdmem2: FPM
[ 1.000000] spdmem2: 0 rows, 0 cols, 0 banks, 0ns tRAC, 0ns tCAC
[ 1.000000] adm1026hm0 at iic0 addr 0x2e: ADM1026 hardware monitor: rev. 0x4, step. 0x5
[ 1.000000] adm1026hm0: 6 fans, 3 temperatures, 15 voltages
[ 1.000000] admtemp3 at iic0 addr 0x38: MAX1617A temperature sensor: id. 0x4d, rev. 0x01
[ 1.000000] spdmem3 at iic0 addr 0x39
[ 1.000000] spdmem3: FPM
[ 1.000000] spdmem3: 0 rows, 0 cols, 0 banks, 0ns tRAC, 0ns tCAC
[ 1.000000] hardare-monitor (i2c-smm150) at iic0 addr 0x40 not configured
[ 1.000000] hardare-monitor (i2c-smm150) at iic0 addr 0x41 not configured
[ 1.000000] hardare-monitor (i2c-smm150) at iic0 addr 0x42 not configured
[ 1.000000] hardare-monitor (i2c-smm150) at iic0 addr 0x43 not configured
[ 1.000000] hardare-monitor (i2c-smm150) at iic0 addr 0x44 not configured
[ 1.000000] hardare-monitor (i2c-smm150) at iic0 addr 0x45 not configured
[ 1.000000] spdmem4 at iic0 addr 0x48
[ 1.000000] spdmem4: DDR SDRAM (registered), data ECC, 1GB, 333MHz (PC-2700)
[ 1.000000] spdmem4: 13 rows, 12 cols, 1 ranks, 4 banks/chip, 6.0ns cycle time
[ 1.000000] spdmem4: tAA-tRCD-tRP-tRAS: 1-3-3-7
[ 1.000000] spdmem4: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] spdmem5 at iic0 addr 0x49
[ 1.000000] spdmem5: DDR SDRAM (registered), data ECC, 1GB, 333MHz (PC-2700)
[ 1.000000] spdmem5: 13 rows, 12 cols, 1 ranks, 4 banks/chip, 6.0ns cycle time
[ 1.000000] spdmem5: tAA-tRCD-tRP-tRAS: 1-3-3-7
[ 1.000000] spdmem5: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] spdmem6 at iic0 addr 0x4a
[ 1.000000] spdmem6: DDR SDRAM (registered), data ECC, 1GB, 333MHz (PC-2700)
[ 1.000000] spdmem6: 13 rows, 12 cols, 1 ranks, 4 banks/chip, 6.0ns cycle time
[ 1.000000] spdmem6: tAA-tRCD-tRP-tRAS: 1-3-3-7
[ 1.000000] spdmem6: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] spdmem7 at iic0 addr 0x4b
[ 1.000000] spdmem7: DDR SDRAM (registered), data ECC, 1GB, 333MHz (PC-2700)
[ 1.000000] spdmem7: 13 rows, 12 cols, 1 ranks, 4 banks/chip, 6.0ns cycle time
[ 1.000000] spdmem7: tAA-tRCD-tRP-tRAS: 1-3-3-7
[ 1.000000] spdmem7: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] seeprom3 at iic0 addr 0x4c: cpu-fru-prom: size 8192
[ 1.000000] lmtemp1 at iic0 addr 0x4d: hardware-monitor LM75 Temperature Sensor
[ 1.000000] seeprom4 at iic0 addr 0x53: nvram: size 8192
[ 1.000000] seeprom5 at iic0 addr 0x54: rmc-fru-prom: size 8192
[ 1.000000] seeprom6 at iic0 addr 0x55: motherboard-fru-prom: size 8192
[ 1.000000] spdmem8 at iic0 addr 0x58
[ 1.000000] spdmem8: DDR SDRAM (registered), data ECC, 1GB, 333MHz (PC-2700)
[ 1.000000] spdmem8: 13 rows, 12 cols, 1 ranks, 4 banks/chip, 6.0ns cycle time
[ 1.000000] spdmem8: tAA-tRCD-tRP-tRAS: 1-3-3-7
[ 1.000000] spdmem8: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] spdmem9 at iic0 addr 0x59
[ 1.000000] spdmem9: DDR SDRAM (registered), data ECC, 1GB, 333MHz (PC-2700)
[ 1.000000] spdmem9: 13 rows, 12 cols, 1 ranks, 4 banks/chip, 6.0ns cycle time
[ 1.000000] spdmem9: tAA-tRCD-tRP-tRAS: 1-3-3-7
[ 1.000000] spdmem9: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] spdmem10 at iic0 addr 0x5a
[ 1.000000] spdmem10: DDR SDRAM (registered), data ECC, 1GB, 333MHz (PC-2700)
[ 1.000000] spdmem10: 13 rows, 12 cols, 1 ranks, 4 banks/chip, 6.0ns cycle time
[ 1.000000] spdmem10: tAA-tRCD-tRP-tRAS: 1-3-3-7
[ 1.000000] spdmem10: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] spdmem11 at iic0 addr 0x5b
[ 1.000000] spdmem11: DDR SDRAM (registered), data ECC, 1GB, 333MHz (PC-2700)
[ 1.000000] spdmem11: 13 rows, 12 cols, 1 ranks, 4 banks/chip, 6.0ns cycle time
[ 1.000000] spdmem11: tAA-tRCD-tRP-tRAS: 1-3-3-7
[ 1.000000] spdmem11: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] seeprom7 at iic0 addr 0x5c: cpu-fru-prom: size 8192
[ 1.000000] hardware-monitor at iic0 addr 0x5d not configured
[ 1.000000] spdmem12 at iic0 addr 0x60
[ 1.000000] spdmem12: DDR SDRAM (registered), data ECC, 1GB, 333MHz (PC-2700)
[ 1.000000] spdmem12: 13 rows, 12 cols, 1 ranks, 4 banks/chip, 6.0ns cycle time
[ 1.000000] spdmem12: tAA-tRCD-tRP-tRAS: 1-3-3-7
[ 1.000000] spdmem12: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] spdmem13 at iic0 addr 0x61
[ 1.000000] spdmem13: DDR SDRAM (registered), data ECC, 1GB, 333MHz (PC-2700)
[ 1.000000] spdmem13: 13 rows, 12 cols, 1 ranks, 4 banks/chip, 6.0ns cycle time
[ 1.000000] spdmem13: tAA-tRCD-tRP-tRAS: 1-3-3-7
[ 1.000000] spdmem13: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] spdmem14 at iic0 addr 0x62
[ 1.000000] spdmem14: DDR SDRAM (registered), data ECC, 1GB, 333MHz (PC-2700)
[ 1.000000] spdmem14: 13 rows, 12 cols, 1 ranks, 4 banks/chip, 6.0ns cycle time
[ 1.000000] spdmem14: tAA-tRCD-tRP-tRAS: 1-3-3-7
[ 1.000000] spdmem14: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] spdmem15 at iic0 addr 0x63
[ 1.000000] spdmem15: DDR SDRAM (registered), data ECC, 1GB, 333MHz (PC-2700)
[ 1.000000] spdmem15: 13 rows, 12 cols, 1 ranks, 4 banks/chip, 6.0ns cycle time
[ 1.000000] spdmem15: tAA-tRCD-tRP-tRAS: 1-3-3-7
[ 1.000000] spdmem15: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] seeprom8 at iic0 addr 0x64: cpu-fru-prom: size 8192
[ 1.000000] hardware-monitor at iic0 addr 0x65 not configured
[ 1.000000] rscrtc (i2c-ds1307) at iic0 addr 0x68 not configured
[ 1.000000] seeprom9 at iic0 addr 0x6d: pdb-fru-prom: size 8192
[ 1.000000] spdmem16 at iic0 addr 0x70
[ 1.000000] spdmem16: DDR SDRAM (registered), data ECC, 1GB, 333MHz (PC-2700)
[ 1.000000] spdmem16: 13 rows, 12 cols, 1 ranks, 4 banks/chip, 6.0ns cycle time
[ 1.000000] spdmem16: tAA-tRCD-tRP-tRAS: 1-3-3-7
[ 1.000000] spdmem16: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] spdmem17 at iic0 addr 0x71
[ 1.000000] spdmem17: DDR SDRAM (registered), data ECC, 1GB, 333MHz (PC-2700)
[ 1.000000] spdmem17: 13 rows, 12 cols, 1 ranks, 4 banks/chip, 6.0ns cycle time
[ 1.000000] spdmem17: tAA-tRCD-tRP-tRAS: 1-3-3-7
[ 1.000000] spdmem17: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] spdmem18 at iic0 addr 0x72
[ 1.000000] spdmem18: DDR SDRAM (registered), data ECC, 1GB, 333MHz (PC-2700)
[ 1.000000] spdmem18: 13 rows, 12 cols, 1 ranks, 4 banks/chip, 6.0ns cycle time
[ 1.000000] spdmem18: tAA-tRCD-tRP-tRAS: 1-3-3-7
[ 1.000000] spdmem18: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] spdmem19 at iic0 addr 0x73
[ 1.000000] spdmem19: DDR SDRAM (registered), data ECC, 1GB, 333MHz (PC-2700)
[ 1.000000] spdmem19: 13 rows, 12 cols, 1 ranks, 4 banks/chip, 6.0ns cycle time
[ 1.000000] spdmem19: tAA-tRCD-tRP-tRAS: 1-3-3-7
[ 1.000000] spdmem19: voltage SSTL 2.5V, refresh time 7.8us (self-refreshing)
[ 1.000000] seeprom10 at iic0 addr 0x74: cpu-fru-prom: size 8192
[ 1.000000] hardware-monitor at iic0 addr 0x75 not configured
[ 1.000000] pcons at mainbus0 not configured
[ 1.000000] esiop0: switching to single-ended mode
[ 1.000000] WARNING: system needs entropy for security; see entropy(7)
[ 1.000000] timecounter: Timecounter "tick-counter" frequency 1593000000 Hz quality 100
[ 1.000003] timecounter: Timecounter "stick-counter" frequency 10000000 Hz quality 200
[ 1.000016] No counter-timer -- using %stick at 10MHz as system clock.
[ 1.000016] timecounter: Timecounter "clockinterrupt" frequency 100 Hz quality 0
[ 2.496743] uhub0 at usb0: NetBSD (0x0000) OHCI root hub (0x0000), class 9/0, rev 1.00/1.00, addr 1
[ 2.496743] uhub0: 3 ports with 3 removable, self powered
[ 2.496743] uhub1 at usb1: NetBSD (0x0000) OHCI root hub (0x0000), class 9/0, rev 1.00/1.00, addr 1
[ 2.496743] uhub1: 3 ports with 3 removable, self powered
[ 2.496743] uhub2 at usb2: NetBSD (0x0000) OHCI root hub (0x0000), class 9/0, rev 1.00/1.00, addr 1
[ 2.496743] uhub2: 3 ports with 3 removable, self powered
[ 2.496743] uhub3 at usb3: NetBSD (0x0000) EHCI root hub (0x0000), class 9/0, rev 2.00/1.00, addr 1
[ 2.496743] uhub3: 8 ports with 8 removable, self powered
[ 2.496743] scsibus0: waiting 2 seconds for devices to settle...
[ 2.496743] WARNING: lwp 105 (system scsibus0-d) flags 0x20000000: timecounter went backwards from (3 + 0x7a22980ec760047b/2^64) sec to (2 + 0x8c127de55063ff53/2^64) sec in netbsd:mi_switch+0xf0
[ 2.754466] scsibus1: waiting 2 seconds for devices to settle...
[ 2.823133] scsibus2: waiting 2 seconds for devices to settle...
[ 3.283132] uhub4 at uhub3 port 7: vendor 04b4 (0x04b4) product 6560 (0x6560), class 9/0, rev 2.00/0.0b, addr 2
[ 3.403132] uhub4: multiple transaction translators
[ 3.463133] uhub4: 4 ports with 4 removable, self powered
[ 6.223133] cd0 at scsibus0 target 5 lun 0: <ZULUSCSI, CDROM, 2.3W> cdrom removable
[ 6.314661] cd0: sync (50.00ns offset 15), 16-bit (40.000MB/s) transfers
[ 6.863133] entropy: best effort
[ 13.503132] sd0 at scsibus2 target 0 lun 0: <ATA, TK0120GDJXT, HPG0> disk fixed
[ 13.583132] sd0: 111 GB, 114474 cyl, 16 head, 127 sec, 512 bytes/sect x 234441648 sectors
[ 13.683132] sd0: tagged queueing
[ 13.743135] swwdog0: software watchdog initialized
[ 13.803133] WARNING: 4 errors while detecting hardware; check system log.
[ 13.883133] root on sd0a dumps on sd0b
[ 13.933133] root file system type: ffs
[ 13.973133] kern.module.path=/stand/sparc64/11.99.8/modules
[ 15.149866] entropy: ready
v445# envstat
Current CritMax WarnMax WarnMin CritMin Unit
[adm1026hm0]
fan 0: 4115 1323 RPM
fan 1: 4066 1323 RPM
fan 2: 4115 1323 RPM
fan 3: 4066 1323 RPM
fan 4: 4115 1323 RPM
fan 5: 4017 1323 RPM
internal: 29.000 80.000 55.000 -128.000 degC
external 1: 45.000 100.000 80.000 -128.000 degC
external 2: 28.000 100.000 80.000 -128.000 degC
Vbatt: 2.855 4.000 V
V3.3 standby: 3.343 4.440 V
V3.3 main: 3.291 4.440 V
V5.0: 5.124 6.667 V
Vccp: 0.000 3.000 V
V+12: 12.048 16.001 V
V-12: -11.953 2.500 -15.928 V
V3.0 0: 0.988 3.000 V
V3.0 1: 1.176 3.000 V
V3.0 2: 1.494 3.000 V
V3.0 3: 1.800 3.000 V
V3.0 4: 0.000 3.000 V
V3.0 5: 2.517 3.000 V
V2.5 0: 0.029 2.500 V
V2.5 1: 0.000 2.500 V
[admtemp0]
internal: 28.000 127.000 -55.000 degC
external: 48.000 127.000 -55.000 degC
[admtemp1]
internal: 26.000 127.000 -55.000 degC
external: 47.000 127.000 -55.000 degC
[admtemp2]
internal: 26.000 127.000 -55.000 degC
external: 51.000 127.000 -55.000 degC
[admtemp3]
internal: 28.000 127.000 -55.000 degC
external: 48.000 127.000 -55.000 degC
[lmtemp0]
temperature-sensor: 27.500 80.000 degC
[lmtemp1]
hardware-monitor: -5.500 45.500 degC
sc> showenvironment
=============== Environmental Status ===============
--------------------------------------------------------------------------------
System Temperatures (Temperatures in Celsius):
--------------------------------------------------------------------------------
Sensor Status Temp LowHard LowSoft LowWarn HighWarn HighSoft HighHard
--------------------------------------------------------------------------------
C0.P0.T_CORE OK 77 -20 -10 0 108 113 120
C1.P0.T_CORE OK 76 -20 -10 0 108 113 120
C2.P0.T_CORE OK 80 -20 -10 0 108 113 120
C3.P0.T_CORE OK 77 -20 -10 0 108 113 120
C0.T_AMB OK 28 -20 -10 0 60 65 75
C1.T_AMB OK 26 -20 -10 0 60 65 75
C2.T_AMB OK 26 -20 -10 0 60 65 75
C3.T_AMB OK 28 -20 -10 0 60 65 75
FIRE.T_CORE OK 47 -20 -10 0 80 85 92
MB.IO_T_AMB OK 31 -20 -10 0 70 75 82
FIOB.T_AMB OK 27 -20 -10 0 47 52 59
MB.T_AMB OK 31 -20 -10 0 70 75 82
--------------------------------------
Keyswitch:
--------------------------------------
Keyswitch position: NORMAL
--------------------------------------------------------
System Indicator Status:
--------------------------------------------------------
SYS.LOCATE SYS.SERVICE SYS.ACT
--------------------------------------------------------
OFF OFF SLOW BLINK
--------------------------------------------------------
SYS.PSFAIL SYS.OVERTEMP SYS.FANFAIL
OFF OFF OFF
--------------------------------------------
System Disks:
--------------------------------------------
Disk Status Service OK2RM
--------------------------------------------
HDD0 OK OFF OFF
HDD1 NOT PRESENT OFF OFF
HDD2 NOT PRESENT OFF OFF
HDD3 NOT PRESENT OFF OFF
HDD4 NOT PRESENT OFF OFF
HDD5 NOT PRESENT OFF OFF
HDD6 NOT PRESENT OFF OFF
HDD7 NOT PRESENT OFF OFF
----------------------------------------------------------
Fans (Speeds Revolution Per Minute):
----------------------------------------------------------
Sensor Status Speed Warn Low
----------------------------------------------------------
FT0.F0.TACH OK 4115 -- 750
FT1.F0.TACH OK 4066 -- 750
FT2.F0.TACH OK 4066 -- 750
FT3.F0.TACH OK 4066 -- 750
FT4.F0.TACH OK 4066 -- 750
FT5.F0.TACH OK 4066 -- 750
--------------------------------------------------------------------------------
Voltage sensors (in Volts):
--------------------------------------------------------------------------------
Sensor Status Voltage LowSoft LowWarn HighWarn HighSoft
--------------------------------------------------------------------------------
MB.V_+1V0 OK 0.98 0.80 0.85 1.15 1.20
MB.V_+1V2 OK 1.17 0.96 1.02 1.38 1.44
MB.V_+1V5 OK 1.48 1.20 1.27 1.72 1.80
MB.V_+1V8 OK 1.79 1.44 1.53 2.07 2.16
MB.V_+2V5 OK 2.50 2.00 2.12 2.87 3.00
MB.V_+3V3 OK 3.27 2.64 2.80 3.79 3.96
MB.V_+3V3STBY OK 3.33 2.64 2.80 3.79 3.96
MB.V_+5V OK 5.09 4.00 4.25 5.75 6.00
MB.V_+12V OK 12.00 9.60 10.20 13.80 14.40
MB.V_-12V OK -11.96 -14.40 -13.80 -10.20 -9.60
SC.BAT.V_BAT OK 2.84 2.25 2.26 3.75 3.75
--------------------------------------------
Power Supply Indicators:
--------------------------------------------
Supply Active Standby Service
--------------------------------------------
PS0 ON ON OFF
PS1 ON ON OFF
PS2 ON ON OFF
PS3 ON ON OFF
------------------------------------------------------------------------------
Power Supplies:
------------------------------------------------------------------------------
Supply Status Underspeed Overtemp Overvolt Undervolt Overcurrent
------------------------------------------------------------------------------
PS0 OK OFF OFF OFF OFF OFF
PS1 OK OFF OFF OFF OFF OFF
PS2 OK OFF OFF OFF OFF OFF
PS3 OK OFF OFF OFF OFF OFF
----------------------
Current sensors:
----------------------
Sensor Status
----------------------
MB.I_USB0 OK
MB.I_USB1 OK
FIOB.I_USB2 OK
FIOB.I_USB3 OK
MB.FF_POK OK
C0.P0.FF_POK OK
C1.P0.FF_POK OK
C2.P0.FF_POK OK
C3.P0.FF_POK OK