Launched in 2004, dmesgd aims to provide a user-submitted repository of searchable *BSD dmesgs. The dmesg(8) command displays the system message buffer's content, and during boot a copy is saved to /var/run/dmesg.boot. This buffer contains the operating system release, name and version, a list of devices identified, plus a whole host of other useful information. We hope others find this resource useful and further contribute to its growth. Contact us at [ admin at lists dot nycbug dot org ].


Date: 2021-07-20 20:13:11
From: Ken Wellsch
Description: NetBSD/sparc64 9.2 on SunFire V445
[     1.000000] Copyright (c) 1996, 1997, 1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005,
[     1.000000]     2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017,
[     1.000000]     2018, 2019, 2020 The NetBSD Foundation, Inc.  All rights reserved.
[     1.000000] Copyright (c) 1982, 1986, 1989, 1991, 1993
[     1.000000]     The Regents of the University of California.  All rights reserved.

[     1.000000] NetBSD 9.2 (GENERIC) #0: Wed May 12 13:15:55 UTC 2021
[     1.000000]         [_EMAIL_XXXXXXXXXXXXXXXXX]:/usr/src/sys/arch/sparc64/compile/GENERIC
[     1.000000] total memory = 4096 MB
[     1.000000] avail memory = 4003 MB
[     1.000000] timecounter: Timecounters tick every 10.000 msec
[     1.000000] Kernelized RAIDframe activated
[     1.000000] running cgd selftest aes-xts-256 aes-xts-512 done
[     1.000000] mainbus0 (root): SUNW,Sun-Fire-V445 (Sun Fire V445): [_HOSTID_XXXXX]
[     1.000000] cpu0 at mainbus0: SUNW,UltraSPARC-IIIi @ 1592 MHz, CPU id 0
[     1.000000] cpu0: manuf 3e, impl 16, mask 34
[     1.000000] cpu0: system tick frequency 10 MHz
[     1.000000] cpu0: 32K instruction (32 b/l), 64K data (32 b/l), 1024K external (64 b/l)
[     1.000000] cpu1 at mainbus0: SUNW,UltraSPARC-IIIi @ 1592 MHz, CPU id 1
[     1.000000] cpu1: manuf 3e, impl 16, mask 34
[     1.000000] cpu1: system tick frequency 10 MHz
[     1.000000] cpu1: 32K instruction (32 b/l), 64K data (32 b/l), 1024K external (64 b/l)
[     1.000000] memory-controller at mainbus0 not configured
[     1.000000] memory-controller at mainbus0 not configured
[     1.000000] pyro0 at mainbus0: "Fire", rev 3, ign 780, bus A 2 to 9
[     1.000000] pyro0: pci0 at pyro0
[     1.000000] pci0: i/o space, memory space enabled
[     1.000000] ppb0 at pci0 dev 0 function 0: PLX Technology product 8532 (rev. 0xba)
[     1.000000] ppb0: PCI Express capability version 1 <Upstream Port of PCI-E Switch>
[     1.000000] pci1 at ppb0 bus 3
[     1.000000] pci1: i/o space, memory space enabled
[     1.000000] ppb1 at pci1 dev 1 function 0: PLX Technology product 8532 (rev. 0x03)
[     1.000000] ppb1: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x4 @ 2.5GT/s
[     1.000000] pci2 at ppb1 bus 4
[     1.000000] pci2: i/o space, memory space enabled
[     1.000000] ppb2 at pci2 dev 0 function 0: ServerWorks BCM5714/BCM5715 Integral PCI-E to PCI-X Bridge (rev. 0xb5)
[     1.000000] ppb2: PCI Express capability version 1 <PCI-E to PCI/PCI-X Bridge>
[     1.000000] pci3 at ppb2 bus 5
[     1.000000] pci3: i/o space, memory space enabled
[     1.000000] bge0 at pci3 dev 4 function 0: Broadcom BCM5714 Gigabit Ethernet
[     1.000000] bge0: interrupting at ivec 3795
[     1.000000] bge0: HW config 00000015, 00000015, 00000000, 00000000 00000000
[     1.000000] bge0: ASIC BCM5715 A3 (0x9003), Ethernet address [_MAC_XXXXXXXXXX]
[     1.000000] bge0: autoconfiguration error: WARNING: failed to restrict dma range, falling back to parent bus dma range
[     1.000000] bge0: setting short Tx thresholds
[     1.000000] brgphy0 at bge0 phy 1: BCM5714 1000BASE-T/X media interface, rev. 0
[     1.000000] brgphy0: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseT, 1000baseT-FDX, auto
[     1.000000] bge1 at pci3 dev 4 function 1: Broadcom BCM5714 Gigabit Ethernet
[     1.000000] bge1: interrupting at ivec 3796
[     1.000000] bge1: HW config 00000014, 00000014, 00000000, 00000000 00000000
[     1.000000] bge1: ASIC BCM5715 A3 (0x9003), Ethernet address [_MAC_XXXXXXXXXX]
[     1.000000] bge1: autoconfiguration error: WARNING: failed to restrict dma range, falling back to parent bus dma range
[     1.000000] bge1: setting short Tx thresholds
[     1.000000] brgphy1 at bge1 phy 1: BCM5714 1000BASE-T/X media interface, rev. 0
[     1.000000] brgphy1: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseT, 1000baseT-FDX, auto
[     1.000000] ppb3 at pci3 dev 8 function 0: ServerWorks HT1000 PCI/PCI-X Bridge (rev. 0xb4)
[     1.000000] pci4 at ppb3 bus 6
[     1.000000] pci4: i/o space, memory space enabled
[     1.000000] ppb4 at pci1 dev 2 function 0: PLX Technology product 8532 (rev. 0x0a)
[     1.000000] ppb4: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x4 @ 2.5GT/s
[     1.000000] pci5 at ppb4 bus 7
[     1.000000] pci5: i/o space, memory space enabled
[     1.000000] mpt0 at pci5 dev 0 function 0: Symbios Logic SAS1068E (rev. 0x02)
[     1.000000] mpt0: interrupting at ivec 1f96
[     1.000000] mpt0: Phy 0: Link Status Unknown
[     1.000000] mpt0: Phy 0: Link Status Unknown
[     1.000000] scsibus0 at mpt0: 112 targets, 8 luns per target
[     1.000000] ppb5 at pci1 dev 8 function 0: PLX Technology product 8532 (rev. 0xba)
[     1.000000] ppb5: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x8 @ 2.5GT/s
[     1.000000] pci6 at ppb5 bus 8
[     1.000000] pci6: i/o space, memory space enabled
[     1.000000] ppb6 at pci1 dev 9 function 0: PLX Technology product 8532 (rev. 0xba)
[     1.000000] ppb6: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x8 @ 2.5GT/s
[     1.000000] pci7 at ppb6 bus 9
[     1.000000] pci7: i/o space, memory space enabled
[     1.000000] pyro1 at mainbus0: "Fire", rev 3, ign 7c0, bus B 2 to 10
[     1.000000] pyro1: pci8 at pyro1
[     1.000000] pci8: i/o space, memory space enabled
[     1.000000] ppb7 at pci8 dev 0 function 0: PLX Technology product 8532 (rev. 0xba)
[     1.000000] ppb7: PCI Express capability version 1 <Upstream Port of PCI-E Switch>
[     1.000000] pci9 at ppb7 bus 3
[     1.000000] pci9: i/o space, memory space enabled
[     1.000000] ppb8 at pci9 dev 1 function 0: PLX Technology product 8532 (rev. 0x03)
[     1.000000] ppb8: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x4 @ 2.5GT/s
[     1.000000] pci10 at ppb8 bus 4
[     1.000000] pci10: i/o space, memory space enabled
[     1.000000] ppb9 at pci10 dev 0 function 0: Acer Labs M5249 Hypertransport to PCI Bridge (rev. 0x00)
[     1.000000] ppb9: PCI Express capability version 1 <PCI-E to PCI/PCI-X Bridge>
[     1.000000] pci11 at ppb9 bus 5
[     1.000000] pci11: i/o space, memory space enabled
[     1.000000] ohci0 at pci11 dev 28 function 0: Acer Labs M5237 USB 1.1 Host Controller (rev. 0x03)
[     1.000000] ohci0: interrupting at ivec 7ca
[     1.000000] ohci0: OHCI version 1.0, legacy support
[     1.000000] usb0 at ohci0: USB revision 1.0
[     1.000000] ohci1 at pci11 dev 28 function 1: Acer Labs M5237 USB 1.1 Host Controller (rev. 0x03)
[     1.000000] ohci1: interrupting at ivec 7ca
[     1.000000] ohci1: OHCI version 1.0, legacy support
[     1.000000] usb1 at ohci1: USB revision 1.0
[     1.000000] ohci2 at pci11 dev 28 function 2: Acer Labs M5237 USB 1.1 Host Controller (rev. 0x03)
[     1.000000] ohci2: interrupting at ivec 7ca
[     1.000000] ohci2: OHCI version 1.0, legacy support
[     1.000000] ohci2: Clear PME# now
[     1.000000] usb2 at ohci2: USB revision 1.0
[     1.000000] ehci0 at pci11 dev 28 function 3: Acer Labs M5239 USB 2.0 Host Controller (rev. 0x01)
[     1.000000] ehci0: interrupting at ivec 7c9
[     1.000000] ehci0: EHCI version 1.0
[     1.000000] ehci0: 3 companion controllers, 3 ports each: ohci0 ohci1 ohci2
[     1.000000] usb3 at ehci0: USB revision 2.0
[     1.000000] ebus0 at pci11 dev 30 function 0: Acer Labs product 1575, revision 0x00
[     1.000000] rtc0 at ebus0 addr 70-73: mc146818 compatible time-of-day clock: m5823
[     1.000000] aceride0 at pci11 dev 31 function 0: Acer Labs M5229 UDMA IDE Controller (rev. 0xc8)
[     1.000000] aceride0: bus-master DMA support present
[     1.000000] aceride0: primary channel configured to native-PCI mode
[     1.000000] aceride0: using ivec 1fc8 for native-PCI interrupt
[     1.000000] atabus0 at aceride0 channel 0
[     1.000000] aceride0: secondary channel configured to native-PCI mode
[     1.000000] atabus1 at aceride0 channel 1
[     1.000000] ppb10 at pci9 dev 2 function 0: PLX Technology product 8532 (rev. 0x0b)
[     1.000000] ppb10: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x4 @ 2.5GT/s
[     1.000000] pci12 at ppb10 bus 6
[     1.000000] pci12: i/o space, memory space enabled
[     1.000000] ppb11 at pci12 dev 0 function 0: ServerWorks BCM5714/BCM5715 Integral PCI-E to PCI-X Bridge (rev. 0xb5)
[     1.000000] ppb11: PCI Express capability version 1 <PCI-E to PCI/PCI-X Bridge>
[     1.000000] pci13 at ppb11 bus 7
[     1.000000] pci13: i/o space, memory space enabled
[     1.000000] bge2 at pci13 dev 4 function 0: Broadcom BCM5714 Gigabit Ethernet
[     1.000000] bge2: interrupting at ivec 37d6
[     1.000000] bge2: HW config 00000015, 00000015, 00000000, 00000000 00000000
[     1.000000] bge2: ASIC BCM5715 A3 (0x9003), Ethernet address [_MAC_XXXXXXXXXX]
[     1.000000] bge2: autoconfiguration error: WARNING: failed to restrict dma range, falling back to parent bus dma range
[     1.000000] bge2: setting short Tx thresholds
[     1.000000] brgphy2 at bge2 phy 1: BCM5714 1000BASE-T/X media interface, rev. 0
[     1.000000] brgphy2: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseT, 1000baseT-FDX, auto
[     1.000000] bge3 at pci13 dev 4 function 1: Broadcom BCM5714 Gigabit Ethernet
[     1.000000] bge3: interrupting at ivec 37d7
[     1.000000] bge3: HW config 00000014, 00000014, 00000000, 00000000 00000000
[     1.000000] bge3: ASIC BCM5715 A3 (0x9003), Ethernet address [_MAC_XXXXXXXXXX]
[     1.000000] bge3: autoconfiguration error: WARNING: failed to restrict dma range, falling back to parent bus dma range
[     1.000000] bge3: setting short Tx thresholds
[     1.000000] brgphy3 at bge3 phy 1: BCM5714 1000BASE-T/X media interface, rev. 0
[     1.000000] brgphy3: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseT, 1000baseT-FDX, auto
[     1.000000] ppb12 at pci13 dev 8 function 0: ServerWorks HT1000 PCI/PCI-X Bridge (rev. 0xb4)
[     1.000000] pci14 at ppb12 bus 8
[     1.000000] pci14: i/o space, memory space enabled
[     1.000000] ppb13 at pci9 dev 8 function 0: PLX Technology product 8532 (rev. 0xba)
[     1.000000] ppb13: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x8 @ 2.5GT/s
[     1.000000] pci15 at ppb13 bus 9
[     1.000000] pci15: i/o space, memory space enabled
[     1.000000] ppb14 at pci9 dev 9 function 0: PLX Technology product 8532 (rev. 0xba)
[     1.000000] ppb14: PCI Express capability version 1 <Downstream Port of PCI-E Switch> x8 @ 2.5GT/s
[     1.000000] pci16 at ppb14 bus 10
[     1.000000] pci16: i/o space, memory space enabled
[     1.000000] ebus1 at mainbus0
[     1.000000] flashprom at ebus1 addr 0-1fffff not configured
[     1.000000] gpio at ebus1 addr c00008-c00008 not configured
[     1.000000] power at ebus1 addr c0a100-c0a12f ipl 786 not configured
[     1.000000] rmc-comm at ebus1 addr c28000-c28007 ipl 789 not configured
[     1.000000] com0 at ebus1 addr c2c000-c2c007 ipl 787: ns16550a, working fifo
[     1.000000] com0: console
[     1.000000] com1 at ebus1 addr fffff8-ffffff ipl 78a: ns16550a, working fifo
[     1.000000] i2c at mainbus0 not configured
[     1.000000] pcons at mainbus0 not configured
[     1.000000] timecounter: Timecounter "clockinterrupt" frequency 100 Hz quality 0
[     1.000003] timecounter: Timecounter "tick-counter" frequency 1592000000 Hz quality 100
[     1.000003] timecounter: Timecounter "stick-counter" frequency 10000000 Hz quality 200
[     1.000014] No counter-timer -- using %stick at 10MHz as system clock.
[     1.496742] scsibus0: waiting 2 seconds for devices to settle...
[     1.604275] uhub0 at usb0: NetBSD (0000) OHCI root hub (0000), class 9/0, rev 1.00/1.00, addr 1
[     1.704274] uhub0: 3 ports with 3 removable, self powered
[     1.704274] uhub1 at usb1: NetBSD (0000) OHCI root hub (0000), class 9/0, rev 1.00/1.00, addr 1
[     1.811131] uhub1: 3 ports with 3 removable, self powered
[     1.814274] uhub2 at usb2: NetBSD (0000) OHCI root hub (0000), class 9/0, rev 1.00/1.00, addr 1
[     1.921030] uhub2: 3 ports with 3 removable, self powered
[     1.921030] uhub3 at usb3: NetBSD (0000) EHCI root hub (0000), class 9/0, rev 2.00/1.00, addr 1
[     2.024274] uhub3: 8 ports with 8 removable, self powered
[     2.024274] atapibus0 at atabus0: 2 targets
[     2.075201] cd0 at atapibus0 drive 0: <MATSHITADVD-RAM UJ-85JS, , F8W2> cdrom removable
[     2.174274] cd0: drive supports PIO mode 4, DMA mode 2, Ultra-DMA mode 4 (Ultra/66)
[     2.174274] cd0(aceride0:0:0): using PIO mode 4, Ultra-DMA mode 4 (Ultra/66) (using DMA)
[     3.824274] sd0 at scsibus0 target 0 lun 0: <FUJITSU, MAY2073RCSUN72G, 0401> disk fixed
[     3.964274] sd0: 70007 MB, 14100 cyl, 24 head, 423 sec, 512 bytes/sect x 143374738 sectors
[     4.054274] sd0: tagged queueing
[     4.114274] sd1 at scsibus0 target 1 lun 0: <FUJITSU, MAY2073RCSUN72G, 0401> disk fixed
[     4.254274] sd1: 70007 MB, 14100 cyl, 24 head, 423 sec, 512 bytes/sect x 143374738 sectors
[     4.354274] sd1: tagged queueing
[     4.394274] uhub4 at uhub3 port 7: vendor 04b4 (0x4b4) product 6560 (0x6560), class 9/0, rev 2.00/0.0b, addr 2
[     4.504274] uhub4: multiple transaction translators
[     4.564274] uhub4: 4 ports with 4 removable, self powered
[     4.904282] WARNING: 4 errors while detecting hardware; check system log.
[     4.984274] root on sd0a dumps on sd0b
[     5.034274] root file system type: ffs
[     5.084274] kern.module.path=/stand/sparc64/9.2/modules