Launched in 2004, dmesgd aims to provide a user-submitted repository of searchable *BSD dmesgs. The dmesg(8) command displays the system message buffer's content, and during boot a copy is saved to /var/run/dmesg.boot. This buffer contains the operating system release, name and version, a list of devices identified, plus a whole host of other useful information. We hope others find this resource useful and further contribute to its growth. Contact us at [ admin at lists dot nycbug dot org ].


Date: 2022-12-15 03:12:17
From: JE3KMZ
Description: FreeBSD/amd64 on Dell Inc. PowerEdge T110 II
Copyright (c) 1992-2021 The FreeBSD Project.
Copyright (c) 1979, 1980, 1983, 1986, 1988, 1989, 1991, 1992, 1993, 1994
	The Regents of the University of California. All rights reserved.
FreeBSD is a registered trademark of The FreeBSD Foundation.
FreeBSD 13.1-RELEASE-p3 GENERIC amd64
FreeBSD clang version 13.0.0 ([_EMAIL_XXXXX]:llvm/llvm-project.git llvmorg-13.0.0-0-gd7b669b3a303)
VT(vga): resolution 640x480
CPU microcode: updated from 0x29 to 0x2f
CPU: Intel(R) Pentium(R) CPU G645 @ 2.90GHz (2893.55-MHz K8-class CPU)
  Origin="GenuineIntel"  Id=0x206a7  Family=0x6  Model=0x2a  Stepping=7
  Features=0xbfebfbff<FPU,VME,DE,PSE,TSC,MSR,PAE,MCE,CX8,APIC,SEP,MTRR,PGE,MCA,CMOV,PAT,PSE36,CLFLUSH,DTS,ACPI,MMX,FXSR,SSE,SSE2,SS,HTT,TM,PBE>
  Features2=0xd9ae3bf<SSE3,PCLMULQDQ,DTES64,MON,DS_CPL,VMX,EST,TM2,SSSE3,CX16,xTPR,PDCM,PCID,SSE4.1,SSE4.2,POPCNT,TSCDLT,XSAVE,OSXSAVE>
  AMD Features=0x28100800<SYSCALL,NX,RDTSCP,LM>
  AMD Features2=0x1<LAHF>
  Structured Extended Features3=0x9c000400<MD_CLEAR,IBPB,STIBP,L1DFL,SSBD>
  XSAVE Features=0x1<XSAVEOPT>
  VT-x: (disabled in BIOS) PAT,HLT,MTF,PAUSE,EPT,UG,VPID
  TSC: P-state invariant, performance statistics
real memory  = 4294967296 (4096 MB)
avail memory = 4033253376 (3846 MB)
Event timer "LAPIC" quality 600
ACPI APIC Table: <DELL   PE_SC3  >
FreeBSD/SMP: Multiprocessor System Detected: 2 CPUs
FreeBSD/SMP: 1 package(s) x 2 core(s)
random: unblocking device.
ioapic0 <Version 2.0> irqs 0-23
Launching APs: 1
random: entropy device external interface
kbd1 at kbdmux0
WARNING: Device "spkr" is Giant locked and may be deleted before FreeBSD 14.0.
vtvga0: <VT VGA driver>
smbios0: <System Management BIOS> at iomem 0xfe120-0xfe13e
smbios0: Version: 2.7, BCD Revision: 2.7
aesni0: No AES or SHA support.
acpi0: <DELL PE_SC3>
acpi0: Power Button (fixed)
cpu0: <ACPI CPU> on acpi0
hpet0: <High Precision Event Timer> iomem 0xfed00000-0xfed003ff on acpi0
Timecounter "HPET" frequency 14318180 Hz quality 950
Event timer "HPET" frequency 14318180 Hz quality 550
Event timer "HPET1" frequency 14318180 Hz quality 440
Event timer "HPET2" frequency 14318180 Hz quality 440
Event timer "HPET3" frequency 14318180 Hz quality 440
Event timer "HPET4" frequency 14318180 Hz quality 440
Event timer "HPET5" frequency 14318180 Hz quality 440
Event timer "HPET6" frequency 14318180 Hz quality 440
atrtc0: <AT realtime clock> port 0x70-0x77 irq 8 on acpi0
atrtc0: Warning: Couldn't map I/O.
atrtc0: registered as a time-of-day clock, resolution 1.000000s
Event timer "RTC" frequency 32768 Hz quality 0
attimer0: <AT timer> port 0x40-0x43,0x50-0x53 irq 0 on acpi0
Timecounter "i8254" frequency 1193182 Hz quality 0
Event timer "i8254" frequency 1193182 Hz quality 100
Timecounter "ACPI-fast" frequency 3579545 Hz quality 900
acpi_timer0: <24-bit timer at 3.579545MHz> port 0x408-0x40b on acpi0
tpm0: <Trusted Platform Module> iomem 0xfed40000-0xfed44fff on acpi0
tpm: device 0x0000104a rev 0x4e
WARNING: Device "tpm" is Giant locked and may be deleted before FreeBSD 14.0.
pcib0: <ACPI Host-PCI bridge> port 0xcf8-0xcff on acpi0
pci0: <ACPI PCI bus> on pcib0
pcib1: <ACPI PCI-PCI bridge> at device 1.0 on pci0
pci1: <ACPI PCI bus> on pcib1
mfi0: <Drake Skinny> port 0x2000-0x20ff mem 0xc1240000-0xc1243fff,0xc1200000-0xc123ffff irq 16 at device 0.0 on pci1
mfi0: Using MSI
mfi0: Megaraid SAS driver Ver 4.23 
mfi0: 82496 (722341165s/0x0020/info) - Shutdown command received from host
mfip0: <SCSI Passthrough Bus>mfi0: 82497 (boot + 3s/0x0020/info) - Firmware initialization started (PCI ID 0073/1000/9241/1000)
mfi0: 82498 (boot + 3s/0x0020/info) - Firmware version 2.130.404-4659
 on mfi0
mfi0: 82499 (boot + 5s/0x0020/info) - Package version 20.13.1-0240
mfi0: 82500 (boot + 5s/0x0020/info) - Board Revision 03A
mfi0: 82501 (boot + 25s/0x0002/info) - Inserted: PD 04(e0xff/s1)
ehci0: <Intel Cougar Point USB 2.0 controller> mem 0xc1305000-0xc13053ff irq 20 at device 26.0 on pci0
usbus0: EHCI version 1.0
usbus0 on ehci0
pcib2: <ACPI PCI-PCI bridge> at device 28.0 on pci0
pci2: <ACPI PCI bus> on pcib2
pcib3: <ACPI PCI-PCI bridge> at device 28.4 on pci0
pci3: <ACPI PCI bus> on pcib3
bge0: <Broadcom NetXtreme Gigabit Ethernet Controller, ASIC rev. 0x00a200> mem 0xc1100000-0xc110ffff irq 16 at device 0.0 on pci3
bge0: CHIP ID 0x0000a200; ASIC REV 0x0a; CHIP REV 0xa2; PCI-E
miibus0: <MII bus> on bge0
brgphy0: <BCM5722 1000BASE-T media interface> PHY 1 on miibus0
brgphy0:  10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseT, 1000baseT-master, 1000baseT-FDX, 1000baseT-FDX-master, auto, auto-flow
bge0: Using defaults for TSO: 65518/35/2048
bge0: Ethernet address: [_MAC_XXXXXXXXXX]
ehci1: <Intel Cougar Point USB 2.0 controller> mem 0xc1304000-0xc13043ff irq 23 at device 29.0 on pci0
usbus1: EHCI version 1.0
usbus1 on ehci1
pcib4: <ACPI PCI-PCI bridge> at device 30.0 on pci0
pci4: <ACPI PCI bus> on pcib4
vgapci0: <VGA-compatible display> mem 0xc0000000-0xc07fffff,0xc1000000-0xc1003fff,0xc0800000-0xc0ffffff irq 19 at device 3.0 on pci4
vgapci0: Boot video device
isab0: <PCI-ISA bridge> at device 31.0 on pci0
isa0: <ISA bus> on isab0
ichsmb0: <Intel Cougar Point SMBus controller> port 0x3000-0x301f mem 0xc1302000-0xc13020ff irq 19 at device 31.3 on pci0
apei0: <ACPI Platform Error Interface> on acpi0
acpi_tz0: <Thermal Zone> on acpi0
ipmi0: <IPMI System Interface> port 0xca8,0xcac on acpi0
ipmi0: KCS mode found at io 0xca8 on acpi
acpi_syscontainer0: <System Container> on acpi0
acpi_syscontainer1: <System Container> on acpi0
uart0: <16550 or compatible> port 0x3f8-0x3ff irq 4 flags 0x10 on acpi0
uart1: <16550 or compatible> port 0x2f8-0x2ff irq 3 on acpi0
orm0: <ISA Option ROMs> at iomem 0xc0000-0xc7fff,0xcf000-0xcffff,0xd0000-0xd0fff pnpid ORM0000 on isa0
coretemp0: <CPU On-Die Thermal Sensors> on cpu0
est0: <Enhanced SpeedStep Frequency Control> on cpu0
Timecounter "TSC-low" frequency 1446713562 Hz quality 1000
Timecounters tick every 1.000 msec
usbus1: 480Mbps High Speed USB v2.0
mfi0: 82502 (boot + 25s/0x0002/info) - Inserted: PD 04(e0xff/s1) Info: enclPd=ffff, scsiType=0, portMap=00, sasAddr=44332211020usbus0: 480Mbps High Speed USB v2.0
00000,0000000000000000
ugen1.1: <Intel EHCI root HUB> at usbus1
mfid0 on mfi0
mfi0: 82503 (boot + 25s/0x0002/info) - Inserted: PD 05(e0xff/s0)
mfid0: 1906394MB (3904294912 sectors) RAID volume 'FreeBSD11.0' is degraded
smbus0: <System Management Bus> on ichsmb0
smb0: <SMBus generic I/O> on smbus0
ipmi0: IPMI device rev. 0, firmware rev. 1.95, version 2.0, device support mask 0xdf
ipmi0: Number of channels 5
ipmi0: Attached watchdog
ipmi0: Establishing power cycle handler
uhub0 on usbus1
uhub0: <Intel EHCI root HUB, class 9/0, rev 2.00/1.00, addr 1> on usbus1
mfi0: 82504 (boot + 25s/0x0002/info) - Inserted: PD 05(e0xff/s0) Info: enclPd=ffff, scsiType=0, portMap=01, sasAddr=4433221103000000,0000000000000000
ugen0.1: <Intel EHCI root HUB> at usbus0
mfi0: 82505 (boot + 25s/0x0020/WARN) - PD missing: SasAddr=0x0, ArrayRef=0, RowIndex=0x1, EnclPd=0x40, Slot=0.

mfi0: 82506 (722341209s/0x0020/info) - Time established as 11/21/22 10:20:09; (28 seconds since power on)
mfi0: 82507 (722341245s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 0uhub11 00
mfi0: 82508 (722341245s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000  reset (Type 03)
mfi0: 82509 (722341248s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 0 on usbus0
1 00
mfi0: 82510 (722341248s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000  reset (Type 03)
mfi0: 82511 (722341252s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 01 00
mfi0: 82512 (722341252s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000  reset (Type 03)
mfi0: 82513 (722341255s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 01 00
mfi0: 82514 (722341255s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000  reset (Type 03)
mfi0: 82515 (722341258s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 0uhub1: <Intel EHCI root HUB, class 9/0, rev 2.00/1.00, addr 1> on usbus0
1 00
mfi0: 82516 (722341258s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000  reset (Type 03)
mfi0: 82517 (722341261s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 01 00
mfi0: 82518 (722341261s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000  reset (Type 03)
mfi0: 82519 (722341264s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 01 00
mfi0: 82520 (722341264s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000  reset (Type 03)
mfi0: 82521 (722341267s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 01 00
mfi0: 82522 (722341267s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000  reset (Type 03)
mfi0: 82523 (722341270s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 01 00
mfi0: 82524 (722341270s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000  reset (Type 03)
mfi0: 82525 (722341273s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 01 00
mfi0: 82526 (722341273s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000  reset (Type 03)
Trying to mount root from ufs:/dev/mfid0p2 [rw]...
mfi0: 82527 (722341276s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 01 00
mfi0: 82528 (722341276s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000  reset (Type 03)
mfi0: 82529 (722341279s/0x0002/WARN) - Command timeout on PD 05(e0x40/s0) Path 4433221103000000, CDB: 28 00 e8 b6 cf ff 00 00 01 00
mfi0: 82530 (722341279s/0x0002/WARN) - PD 05(e0x40/s0) Path 4433221103000000  reset (Type 03)
pass0 at mfi0 bus 0 scbus0 target 4 lun 0
pass0: <ATA WDC WD2002FAEX-0 1D05> Fixed Uninstalled SPC-3 SCSI device
pass0: [_SERIAL_NUMBER_XXXXXXXXXXXX]
pass0: 150.000MB/s transfers
pass0: Command Queueing enabled
pass1 at mfi0 bus 0 scbus0 target 5 lun 0
pass1: <ATA WDC WD2003FZEX-0 1A01> Fixed Uninstalled SPC-3 SCSI device
pass1: [_SERIAL_NUMBER_XXXXXXXXXXXX]
pass1: 150.000MB/s transfers
pass1: Command Queueing enabled
uhub0: 2 ports with 2 removable, self powered
uhub1: 2 ports with 2 removable, self powered
ugen0.2: <vendor 0x8087 product 0x0024> at usbus0
uhub2 on uhub1
uhub2: <vendor 0x8087 product 0x0024, class 9/0, rev 2.00/0.00, addr 2> on usbus0
ugen1.2: <vendor 0x8087 product 0x0024> at usbus1
uhub3 on uhub0
uhub3: <vendor 0x8087 product 0x0024, class 9/0, rev 2.00/0.00, addr 2> on usbus1
CPU: Intel(R) Pentium(R) CPU G645 @ 2.90GHz (2893.43-MHz K8-class CPU)
  Origin="GenuineIntel"  Id=0x206a7  Family=0x6  Model=0x2a  Stepping=7
  Features=0xbfebfbff<FPU,VME,DE,PSE,TSC,MSR,PAE,MCE,CX8,APIC,SEP,MTRR,PGE,MCA,CMOV,PAT,PSE36,CLFLUSH,DTS,ACPI,MMX,FXSR,SSE,SSE2,SS,HTT,TM,PBE>
  Features2=0xd9ae3bf<SSE3,PCLMULQDQ,DTES64,MON,DS_CPL,VMX,EST,TM2,SSSE3,CX16,xTPR,PDCM,PCID,SSE4.1,SSE4.2,POPCNT,TSCDLT,XSAVE,OSXSAVE>
  AMD Features=0x28100800<SYSCALL,NX,RDTSCP,LM>
  AMD Features2=0x1<LAHF>
  Structured Extended Features3=0x9c000400<MD_CLEAR,IBPB,STIBP,L1DFL,SSBD>
  XSAVE Features=0x1<XSAVEOPT>
  VT-x: (disabled in BIOS) PAT,HLT,MTF,PAUSE,EPT,UG,VPID
  TSC: P-state invariant, performance statistics
acpi_wmi0: <ACPI-WMI mapping> on acpi0
acpi_wmi0: cannot find EC device
lo0: link state changed to UP
uhub3: 6 ports with 6 removable, self powered
uhub2: 6 ports with 6 removable, self powered
bge0: link state changed to DOWN
ugen1.3: <I-O DATA DEVICE. ETX3-US2> at usbus1
axe0 on uhub3
axe0: <0> on usbus1
miibus1: <MII bus> on axe0
ukphy0: <Generic IEEE 802.3u media interface> PHY 16 on miibus1
ukphy0:  none, 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, auto
ue0: <USB Ethernet> on axe0
ue0: Ethernet address: [_MAC_XXXXXXXXXX]
bge0: link state changed to UP
ue0: link state changed to DOWN